Laserfiche WebLink
09?14.2011 17:12 (209) 465-4988 HMC - Henderson Maint Co Page 5:1 <br />OUTPUT RELAY SETUP <br />R 1:07 SLAVE VSFC <br />TYPE: <br />PUMP CONTROL OUTPUT <br />TANK 0: 1 <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ISD SITE ALARMS <br />TSD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:OVERFILL ALARM <br />TYPE: <br />STANDARD <br />NORMALLY OPEN <br />TANK #: NONE <br />IN -TANK ALARMS <br />ALL:OVERFILL ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:MAX PRODUCT ALARM <br />PLLD LINE DISABLE SETUP <br />Q 1 :91 <br />LIQUID SENSOR ALMS <br />ALL:FUEL "LARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ISD SITE ALARMS <br />FSP GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />Q 2:87 <br />LIQUID SENSOR ALMS <br />ALL:FUEL ALARM <br />ALL:SENSOR OUT ALARM <br />ALL:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />SMARTSENSOR SETUP <br />s 1:DISP 1-2 AFM <br />CATEGORY AIR FLOW METER <br />s 2:DISP 3-4 <br />CATEGORY AIR FLOW METER <br />s 3:DISP 5-6 <br />CATEGORY A I R FLOW METER <br />s 4:DISP 7-8 <br />CATEGORY AIR FLOW METER <br />s 5:VAPOR SENSOR <br />CATEGORY VAPOR PRESSURE <br />EVR/ISD SETUP <br />EVR TYPE: VACUUM ASSIST <br />VACUUM ASSIST TYPE <br />HEALY VAC <br />NOZZLE A/L RANGE <br />MAX: 1.15 MIN: 0.95 <br />VAPOR PROCESSOR TYPE <br />NO VAPOR PROCESSOR <br />ANALYSIS TIMES <br />TIME: 11:00 P11 <br />DELAY MINUTES: 1 <br />ACCEPT HIGH ORVR: <br />DISABLED <br />ISD <br />HOSE <br />TABLE <br />ID <br />FP <br />FL <br />HL <br />AA <br />RR <br />------------------------ <br />01 <br />01 <br />01 <br />02 <br />01 <br />UU <br />02 <br />02 <br />02 <br />02 <br />01 <br />UU <br />03 <br />03 <br />03 <br />02 <br />02 <br />UU <br />04 <br />04 <br />04 <br />02 <br />02 <br />UU <br />05 <br />05 <br />05 <br />02 <br />03 <br />UU <br />06 <br />06 <br />06 <br />02 <br />03 <br />UU <br />07 <br />07 <br />07 <br />02 <br />04 <br />UU <br />08 <br />08 <br />08 <br />02 <br />04 <br />UU <br />ISD AIRFLOW METER MAP <br />ID SERIAL NUM LABEL <br />- <br />1 20611 - -MSP 1-2 A <br />2 14916 DISP 3-4 <br />3 26335 DISP 5-6 <br />4 51627 DISP 7-8 <br />ISD FUEL GRADE HOSE MAP <br />1 2 3 4 <br />FP MHH MHH MHH 111HH AA <br />01 501-301 901 U U 1 <br />02 502 30.2 902 4 U 1 <br />03 503 303 903 U U 2 <br />04 504 304 904 U U 2 <br />05 505 305 905 U U 3 <br />06 506 :306 906 U U 3 <br />07 507 307 907 U U 4 <br />08 508 308 908 U U 4 <br />LABEL TABLE <br />1: UNASSIGNED <br />2: BLEND'S <br />3: REGULAR <br />4: MID GRADE <br />5: PREMIUM <br />6: GOLD <br />7: BR014ZE <br />8: SILVER <br />9: BLEND2 <br />10: BLEND4 <br />PMC SETUP <br />PROCESSOR CONTROL LEVEL: <br />NONE <br />