My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:57:54 PM
Creation date
3/20/2019 4:29:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />A,Prr` STATIOf'tB26a'1* <br />�n c +,rni cnn� �n,rpY cTn{�VTnn' <br />nary 12, 201r <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />Hn approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the designated <br />operator monthly inspection report and failed to check that they were responded to appropriately. The Q2 87 <br />electronic line leak detector alarmed on 12-25-15 and 12-3-15. The Q1 91 electronic line leak detector alarmed on <br />9-20-15 and 8-24-15. The facility and the designated operator did not document these alarms. The designated <br />operator did not document a response to these alarms. During the monthly inspection, the designated operator <br />shall review the alarm history for the previous month, check that each alarm was documented and responded to <br />appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br />monthly report. Ensure that designated operators performing monthly inspections at this facility are including all of <br />the required information on the reports. <br />This is a minor violation. <br />Oz <br />CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />business operato I derations c . The A; ._ was not <br />found on site during the inspection. Designated operator monthly inspection reports for the previous twelve months <br />shall be retained on site. Locate and ensure that copies of the previous twelve months of designated operator <br />monthly inspection reports are maintained on site. Submit copies to the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />site to conduct a routine underground storage tank (UST) inspection and witness the annual monitoring <br />System certification testing. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 2-12-16. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Received by <br />Inspector: <br />Phone: <br />Date: <br />(initial): I+� <br />ARIS VELOSn �onin� PFHS <br />01!12/2016 <br />Page 5 of 6 <br />
The URL can be used to link to this page