My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3264
>
1600 - Food Program
>
PR0162840
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 2:18:56 PM
Creation date
3/21/2019 9:16:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0162840
PE
1625
FACILITY_ID
FA0001886
FACILITY_NAME
KENTUCKY FRIED CHICKEN #206
STREET_NUMBER
3264
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209-2737
CURRENT_STATUS
01
SITE_LOCATION
3264 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C3 <br /> C6 <br /> C26 � o <br /> C6 C6 <br /> M-3 <br /> o F-2 F-2 <br /> C2 O C9 T-1 <br /> D-1 <br /> NUNN <br /> C11 TR-2 C12 ago fiple; <br /> TYP <br /> C5 C15 <br /> C14 C21 O <br /> o C25 D- 0 -0 C6 <br /> U Z <br /> LU o <br /> H U <br /> CO <br /> 0 C17 <br /> Uz <br /> w0 <br /> C1 '0/1 L-1 O O TR 4 TO-1 VMI JOB NUMBER <br /> C)caC22 <br /> _.� <br /> LL T- <br /> 1893 <br /> = TR-4 0LU <br /> -1 <br /> Z CD C24 C11 <br /> w o <br /> w C24 <br /> w 0 L-1 0 S <br /> �w <br /> TR-4 <br /> o <br /> m C2 C11 C7 C17 <br /> �a <br /> 0 D-1 C6 <br /> LU a <br /> 0 0 <br /> < L-1 p_0 0 D- D- -1 <br /> w U <br /> a oR <br /> i� <br /> C17 0 C4 C20 <br /> Z o p_1 C5 C21 <br /> ap <br /> �o <br /> LU <br /> 14 U2d <br /> Z� <br /> C19 C15 C28 3-0" <br /> OD C5 <br /> C15 TR 4 <br /> o� C28 / 0 0 <br /> � I <br /> O wI D-1 D-1 <br /> \ F-1 <br /> w <br /> 0 D-1 -1 <br /> W LU <br /> 0 0 vM, architecture <br /> M-3 D-1 D-1 D-1 <br /> a 0 0 C16 Design Planning Interiors <br /> LU <br /> o� <br /> < C26 D-1 TYP <br /> 637 5th Avenue San Rafael, CA 94901 <br /> 0 0 415-451-2500 415-451-2595 fax <br /> U) 0 0 0 www.vmarch.com <br /> � o Z / L-3 L-3 3'-0" C11 D D-1 L <br /> m� <br /> o i C11 <br /> C11 <br /> U)� <br /> S O <br /> CV � <br /> Q9 �9 T-1 0 <br /> wLL] - D-1 TO/-2 TR-2 TR-2 D <br /> m� <br /> Oat. J F= <br /> � Q} <br /> o m <br /> AR <br /> a o [ElC16 T-1 T-1 P q T-1 o T-1 <br /> E_ � <br /> N - <br /> co o z ® F-2 F-2 ® F-2 ® F-2 <br /> U)0 * x No. C17928 <br /> woCD U <br /> a z C14 C27 aC <br /> 25 M-3 C6 REN. 10/31/19 <br /> a O C5 <br /> 2 z o 27 C14 <br /> U)Uj"Uj C15 OF CAO <br /> L ZD C26 <br /> C25 <br /> = o 2E LEGEND GENERAL NOTES <br /> =0 <br /> � U� <br /> U LL <br /> o o EXISTING TO REMAIN A. RESTROOMS- PAINT HARD LID CEILING AND WALLS. STEAM CLEAN FLOOR REFLECTED CEILING PLAN <br /> _C� oQ TILE AND RE-LAMP/RE-LENSE LIGHT FIXTURES. NORTH <br /> Z Z> Scale: 1/4" = V-0" <br /> J w a NO WORK IN THIS AREA B. NO STRUCTURAL ELEMENTS TO BE REMOVED. G.C.TO NOTIFY ARCHITECT <br /> 3 o IMMEDIATELY OF ANY STRUCTURAL ISSUES IDENTIFIED IN THE FIELD. <br /> a-o <br /> LL w <br /> J0 LL <br /> Ujo C. REFER TO A-2.0 EXTERIOR ELEVATIONS FOR WALL SCONCE LOCATIONS <br /> U z <br /> w d m <br /> N <br /> LU N <br /> 0 ==) <br /> LL, =w <br /> LU o O REFLECTED CEILING PLAN KEY NOTES GENERAL NOTES - LIGHTING / ELECTRICAL LIGHTING SCHEDULE <br /> o <br /> U LL <br /> LL <br /> J v= <br /> LL_ <br /> =o C1. REINSTALL EXISTING MENU BOARD C23. RELOCATE EXISTING T-STAT AS NEEDED A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER P. E.C. SHALL PROVIDE J-BOX FOR SIGNAGE BY SIGN VENDOR. N0. QTY. LOCATION MRG/CATALOG NUMBER DESCRIPTION WATTS/ <br /> o a VOLTS <br /> Z o FINAL CONNECTION TO BUILDING POWER BY E.C. ELITE: B61C AT W REVISION: <br /> C2. NEW STAINLESS STEEL CAP AT UNDERSIDE OF EXISTING BULKHEAD C24. NO WORK IN THIS AREA B. EMERGENCY AND STANDARD LIGHTING MARKED WITH "NL" 6"IC AIR SHUT RECESSED CAN WITH MEDIUM BASE SOCKET <br /> Q a SUBSCRIPT SHALL OPERATE CONTINUOUSLY: PROVIDE Q. E.C. SHALL PROVIDE J-BOX FOR NEW EXTERIOR LIGHT D-1 31 SALES FLOOR (HOUSING) AND HANGER BARS,WHITE 6"3000K 95 CRI TRIM WITH QUICK 14 WATTS/ Mark Date By <br /> I z z TCP: 70874 120 VOLTS <br /> 0 o C3. WIRING OF LIGHTS IN CANOPY BY VENDOR. E.C. SHALL MAKE FINAL CONNECTION TO EXISTING LIGHTING C25. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURE IN RESTROOMS, BEHIND SERVICE UNSWITCHED HOT TO STANDARD AND EMERGENCY FIXTURE. FINAL CONNECTION TO BUILDING POWER BY E.C. CONNECT PLUG 09/04/2018 DH <br /> C=) az <br /> o CIRCUIT THIS AREA COUNTER AND ENTRY BALLASTS <br /> f LED14DR5630K95 <br /> R. E.C. SHALL COORDINATE EXACT ROUTING OF ALL NEW TECH UPDATE PREVIOUS FOR PERMIT SUBMITTAL <br /> rn 20-0 <br /> o C4. NEW RECESSED LIGHTING-CENTERED ABOVE TABLES-CONNECT TO EXISTING DINNING ROOM LIGHT C26. NEW WALL PACK LIGHT ABOVE DOOR C. EMERGENCY LIGHTING NOT MARKED WITH "NL" SUBSCRIPT: AND RELOCATED CIRCUITS. FIELD VERIFY EXISTING F-1 1 DINING AREA 700TDSOCOP-M-08-R-B/ SOCO PENDANT 8'WHITE CORD WITH BLACK MODERN 10 WATTS/ <br /> 00 0 05 SOCKET-PART OF IS-1 (SEE SCHD-2 KFC DECOR SCHEDULE) 120 VOLTS <br /> 0-0 CIRCUITS PROVIDE UNSWITCHED CONSTANT HOT TO EMERGENCY CONDITIONS. ALL WORK AND WIRING PER NEC 700TDMRD-3-T-B <br /> a C27. EXISTING GYPSUM BOARD CEILING. PATCH AND REPAIR AS REQUIRED BALLAST AND SWITCHED HOT TO STANDARD BALLAST INSTALLATION REQUIREMENTS. ALL WORK TO BE <br /> w z GLASS PENDANT WITH BRUSHED NICKEL FINISH MEDIUM 3 WATTS/ <br /> L o o C5. EXISTING CEILING RECEPTACLES TO BE REPLACED WITH NEW CONCEALED. SURFACE MOUNT RACEWAYS ARE NOT F-2 6 SALES FLOOR MINKA:2260-84 BASE SOCKET 120 VOLTS <br /> 0 N C28. NEW RECESSED LIGHTING-CONNECT TO EXISTING LIGHT CIRCUITS D. CONTRACTOR SHALL FIELD VERIFY CEILING TYPE AND PERMITTED <br /> �I a C6. NEW EXTERIOR AWNING/LOUVER, REFER TO EXTERIOR ELEVATIONS PROVIDE PROPER MOUNTING HARDWARE <br /> C29. S. DRAWINGS ARE BASED ON EXISTING CONDITIONS T-1 10 SALES FLOOR JUNO: R600L3HCNWH VERTICAL INTEGRADED LED TRACK LIGHT WHITE FINISH 10 WATTS/ <br /> UI O a C7. CUSTOM MILLWORK, FAUX WOOD BEAMS- MODIFY EXISTING SOFFIT/CEILING AS E. ALL LIGHT FIXTURES SHALL BE SUPPLIED WITH LAMPS PROVIDED BY LEND LEASE. THE ARCHITECT ASSUMES NO 3000K HI CRI 23 DEGREE NARROW BEAM 120 VOLTS <br /> CO <br /> 0 o NEEDED TO ACCOMMODATE NEW BEAM C30. RESPONSIBILITY FOR THE ACCURACY OF THAT <br /> w F. ELECTRICAL CONTRACTOR SHALL VERIFY AVAILABLE INFORMATION. DISCREPANCIES FOUND IN THE FIELD ARE MENU BOARD VERTICAL INTEGRADED LED WALL WASHER TRACK LIGHT 35 WATTS/ <br /> T-2 2 CONTECH: CTL181V3CDP <br /> rvic�Tini� i ini ITTlI nrnnnini <br /> o z C8. EXISTING SOFFIT TO BE PAINTED (P-6) C31. CIRCUITS IN ELECTRICAL PANELS AND REUSE EXISTING TO BE RESOLVED ON SITE BY THE CONSTRUCTION LIGHT 3000K HI CRI 120 VOLTS <br /> Uw a CIRCUITS AS AVAILABLE MANAGER IN CONJUNCTION WITH THE LEND LEASE <br /> up ,w C9. NEW EMERGENCY LIGHTING &EXIT SIGNAGE (WHITE BACKGROUND) PROJECT MANAGER. TRACK 4 SALES FLOOR CONTECH:TR-2 SINGLE CIRCUIT LINE VOLTAGE TRACK WHITE FINISH <br /> N a m G. CONNECT LIGHTING CIRCUITS TO EXISTING LIGHTING <br /> �I w z C10. NEW BUCKET PENDANT LIGHT AND LIGHT RING CONTROL PANEL. COORDINATE CONTROL SEQUENCE AND T. GENERAL CONTRACTOR TO PROVIDE MINIMUM 2"X8" <br /> LL LL TIME OF DAY SCHEDULING WITH FRANCHISEE (NOMINAL) BACKING AT EACH CANOPY ATTACHMENT TRACK 5 SALES FLOOR CONTECH:TR-4 SINGLE CIRCUIT LINE VOLTAGE TRACK WHITE FINISH <br /> U) <br /> w C11. NEW TRACK LIGHTING- POSITION AT 3'-0" FROM WALL U.N.O. POINT. CANOPY IS TO BE SECURED WITH THRU BOLT, LOCK <br /> Co H. EXISTING 2X4 AND 2X2 LIGHTING TO BE RE-LENSED AND WASHER AND NUT INTO BACKING SALES FLOOR PROJECT TITLE <br /> _ J C12. NEW PENDANT LIGHTING CENTERED ABOVE TABLE RE-LAMPED (WITH LED) L-1 3 RECESSED MOBERN: 2X4 LED EDGELIT FLAT PANEL 3500K 4 WATTS/ <br /> TROFFER MFPEL24LED50DMVWH35 120 VOLTS K-38 VISION 3.0 TO <br /> �I a o C13. PAINT CEILING (P-6) I. REFER TO A2.0 FOR ADDITIONAL EXTERIOR LIGHTS NOT AMERICAN SHOWMAN" <br /> O 1 SHOWN ON PLAN RESTROOM MOBERN: 37 WATTS/ <br /> 0-11 C14. INSTALL NEW HVAC DIFFUSERS AND GRILLES (WHITE) L-3 2 RECESSED MFPEL14LED37DMVWH35 1X4 LED EDGELIT FLAT PANEL 3500K WITH FLANGE KIT 120 VOLTS TEMPLATE VERSION <br /> 6n o o J. ALL NEW LIGHTING TO BE COORDINATED WITH EXISTING TROFFER MOBERN: SMKT14 MFPEL RELEASE 2.0 JAN. 2017 <br /> �I a z C15. NEW CEILING TILES AND GRIDS MECHANICAL GRILLES <br /> m o EXTERIOR FIXTURES REFER TO EXTERIOR ELEVATIONS FOR LOCATIONS HMC #206 CONLEY <br /> o w C16. PAINT EXISTING SPEAKERS (P-6) K. EXISTING ELECTRICAL PANEL LOCATIONS&NEW CIRCUITS <br /> = o o SHALL BE VERIFIED BY E.C. E.C. SHALL COORDINATE& 3264 W. HAMMER LANE <br /> 00 w C17. RELOCATED DIFFUSERS,ADJUST SUPPLY LINE TO FEED NEW DIFFUSER VERIFY FINAL ELECTRICAL WITH LIGHTING/SIGNAGE STOCKTON, CA. 95209 <br /> SUPPLIERS NO. QTY. LOCATION MRG/CATALOG NUMBER DESCRIPTION WATTS/ <br /> w C18. INSTALL NEW PEPSI SIGN VOLTS KFC ENTITY NO. E720350 <br /> L. PROVIDE ESCUTCHEON PLATES AND SEALANT AT ALL <br /> o =w C19. REINSTALL EXISTING WI-FI ROUTER IN SAME LOCATION UTILITY PENETRATIONS OF WALLS, CEILINGS,AND FLOORS. <br /> ISSUE DATE 09/04/2018 <br /> o DO NOT USE CAULK OR EXPANDING FOAM FOR SEALANT AMERLUX:WAF1/30/BLK SINGLE ARRAY LED FLOOD LIGHT 3000K BLACK <br /> C20. REINSTALL EXISTING BUG LIGHTS (LIGHT) 24 WATTS/ SHEET TITLE <br /> o E-1 16 TOP OF WALL FINISH WITH CUSTOM 36"ARM BRACKET BLACK <br /> M. ALL WIRING TO BE PER NEC INSTALLATION AMERLUX:WAF1/BLDG 120 VOLTS <br /> a o= C21 . EXISTING CCTV'S/CAMERA'S/SMOKE DETECTORS TO BE RELOCATED BY OWNER'S VENDOR AS NEEDED REQUIREMENTS SIZED FOR 40% MAX FILL PER NEC MNT/BLK-361N (BRACKET) FINISH REFLECTED <br /> Z <br /> m Z a C22. REINSTALL EXISTING ELECTRICAL(LED PANELS) MENU BOARD BY OWNER VENDOR N. RELOCATED DEVICES TO BE ROUTED IN FLEXIBLE METAL AMERLUX FL1/HWS/30/BLK(LIGHT) SINGLE ARRAY LED FLOOD LIGHT 3000K BLACK 31 WATTS/ CEILING PLAN <br /> CONDUIT. <br /> E-2 3 ABOVE BANNER PANEL AMERLUX:WAF1/BLDG FINISH WITH CUSTOM 48"ARM BRACKET BLACK 120 VOLTS <br /> o z MNT/BLK-481N(BRACKET) FINISH HORIZONTAL WIDE SPOT BEAM <br /> a- <br /> a0. PROVIDE NEW OR EXTEND EXISTING POWER/DATA/PHONE <br /> 001 ?o <br /> w LINES FOR NEW MODIFIED LAYOUT. G.C./E.C. IS M-3 3 WALL SCONCE RAB:WPLED20Y EXTERIOR RATED LED WALL PACK 3000K BLACK 20 WATTS/ <br /> oLL'wRESPONSIBLE FOR FIELD VERIFYING THE EXISTING FINISH 120 VOLTS <br /> Z <br /> ELECTRICAL CAPACITY AND CONFIRMING THAT THE <br /> cu 0- o NUMBER OF SPARES AT THE PANELS IS ADEQUATE FOR SHEET NO. <br /> E az <br /> U O THE ADDITION/RELOCATION OF THE SERVICES SHOWN. G.C. <br /> Co CD= w w TO NOTIFY KFC PM IF EITHER SERVICE OR NUMBER OF <br /> Cv o o SPARES IS FOUND TO NOT MEET THE NECESSARY <br /> w w REQUIREMENTS <br /> ©2018 VMI Architecture <br />
The URL can be used to link to this page
Your browser does not support the video tag.