Laserfiche WebLink
oPaU N c SAN J O A Q U I N Environmental Health Department <br /> L <br /> = s — o ," <br /> a ` COUNTY Linda Turkatte REHS Director <br /> . ; > <br /> Cq <br /> FO ... <br /> . Greatness grows here . Kasey Foley, REHS, Assistant Director <br /> j <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco, REHS, RDI <br /> Michael Kith, REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> March 21 , 2019 <br /> ROBERT SILLS <br /> JONES COVEY GROUP , INC <br /> 9595 LUCAS RANCH RD # 100 <br /> RANCHO CUCAMONGA, CA 91730 <br /> Re : FLYING J TRAVEL PLAZA #618* SR0080134 <br /> 1501 N JACK TONE RD <br /> RIPON , CA 95366 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the application for <br /> a permit to replace drop tubes in diesel , auto diesel , 87 and 91 tanks with Franklin Fueling ( Defender Series) drop <br /> tubes and in biodiesel tank with OPW (71SO-420 CT) drop tube on the underground storage tank ( UST) system <br /> at the above noted address. The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones . <br /> 3 . Contact Zuna Barker at (209) 953-7311 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments) . <br /> Overfill prevention verification : Measurement of drop tubes to verify 95% tank volume shut off. If ball <br /> floats are installed , verification that they do not interfere with drop tubes operation . <br /> Please be aware that the facility cannot receive fuel in the diesel , auto diesel , biodiesel, 87 , and <br /> 91 tank prior to the EHD inspection and approval . <br /> 4 . If concrete will be broken near the diesel , auto diesel , biodiesel , 87 , and 91 tank, a secondary <br /> containment test must be performed on the diesel , auto diesel , biodiesel , 87 , and 91 tank once <br /> concrete is poured in accordance with the manufacturer's guidelines . <br /> 5 . Any individual performing the work of a service technician must meet the following qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , current <br /> contractor's licenses issued by the Contractors State License Board (may be issued to the <br /> installation company) , or a Tank Tester's license issued to the individual by the State Water <br /> Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically present at <br /> the work site who possesses a valid , current California UST Service Technician certificate issued <br /> by the International Code Council ( ICC) , and <br /> C. Possesses a valid , current certificate of training from the manufacturer(s) of the component(s) <br /> being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br />