Laserfiche WebLink
4" CONCRETE SLAB IN 2' CHAMFER <br /> LANDSCAPE AREA REINFORCED CORNERS (TYP) Documents prepared by Core FES <br /> W/ WELDED WIRE FABRIC WWF States Engineering are of ct used <br /> only for the specific project and <br /> 6" x 6" W1.4 x W1.4 (WWF) <br /> a specific use for which they are CORE STATES <br /> O � <br /> intended. Any extension of use to <br /> other projects, by owner or any 34319 <br /> 0 other party, without the expressed, <br /> SLOPE 02 written consent of Core States <br /> I PP2 Engineering is done at the user's <br /> own risk. If used in a way other 1700 Industrial Drive,suite B G R O U P �qT F�HANIC�O <br /> MW than that specifically intended, user Rogers,AR 72756 OFCA <br /> ° TYPE 40 BC FIRE EXTINGUISHER TO will hold Core States Engineering Phone(479)986-4400 /Y <br /> NOTE: / \ BE INSTALLED AT TANK STORAGEharmless from all claims and losses. FAX(479)986-4401 <br /> DIMENSIONS ARE TO AREA PER LOCAL JURISDICTION <br /> BE USED FOR A <br /> MINIMUM AREA OF <br /> COVERAGE OVER <br /> BIO-DIESEL IN FROM NEW <br /> TANKS. CONCRETE 20,000 GAL TANK <br /> OVER TANKS IS TO MULTI PORT MANHOLE FOR <br /> BE 4" THICK <br /> REINFORCED FILL/VAPOR (SEE DETAIL <br /> CONCRETE SLAB 03/PP3) = = <br /> REINFORCED WITH #4 / <br /> BARS 12" O.C.E.W. / �o-DIESELT K <br /> 3 / VENT STACK W/SUMP TYP (1) o <br /> O O CHASE FROM <br /> / SEE DETAIL 01/PP1.1 DESEL T K s� <br /> NOTE: <br /> ADDITIONAL KA KA <br /> REINFORCING AT <br /> EACH MANHOLE, #4 Y <br /> Z MANHOLE FOR CHASE PIPE FROM <br /> BARS 6'-0" LONG Q Q Q EXISTING DIESEL TANK <br /> 8" O.C.E.W. '`�� E` '`�� � �' TANK LEVEL SENSOR (TYP (1) BIO-DIESEL OUT TO ° <br /> co Y 00 _J TANK) SEE DETAIL 02/PP4 EXISTING TRUCK DIESEL i �� STP FOR VACUUM LINE <br /> 6'-0" MIN. IN ALL I Z I w � <br /> DIRECTIONS J 3W J DI FROM EXISTING <br /> i� Q cn �� °� DIESEL TANK FARM p <br /> FROM CENTER OF _J o ° L <br /> MANHOLE. TIE J <br /> TO SLAB < m MANHOLE AT <br /> REINFORCING. BIO–DIESEL DISCHARGE MANWAY �3 <br /> (SEE DETAIL 01/PP3) 3 ° ° <br /> 3 <br /> NOTE: ADDITIONAL REINFORCEMENT AT EACH— <br /> ADDITIONAL <br /> ACH ADDITIONAL 01 01 18" MANHOLE #4 BAR 4'-0" LONG ° D <br /> REINFORCING AT PP2 PP2 8" 0.C.E.W. ° <br /> EACH 18"4 <br /> MANHOLE, #4 BIO-DIESEL SHED ° <br /> BARS 4'-0" <br /> LONG 8" O.C.E.W. 18"4 MANHOLE FOR <br /> 3/8)) = 1 —0 44'D1TIONAL MANHOLEEI#4OBARM6'N 0 'A LONG <br /> ° � <br /> TIE TO SLAB INTERSTITIAL TANK <br /> REINFORCING. MONITORS <br /> 8" O.C.E.W. 6'-0" MIN ALL DIRECTIONS <br /> Gr FROM CENTER OF MANHOLE T7 4p <br /> (TYP (1) TANK) ° <br /> (SEE DETAIL 04/PP4) NOTE: UNLESS OTHERWISE NOTED ON THESE PLANS OR EXPRESSED BY A ° 1141 <br /> \ / PILOT REPRESENTATIVE, ALL DEADMEN ARE TO BE SUPPLIED BY PILOT ° <br /> WITH TANKS. <br /> OPW 6110-48WT, 48"4 LOMW LEGEND STEEL BOLT–DOWN MANHOLE <br /> IS INTERSTITIAL SENSOR COVER ASSEMBLY WITH ° <br /> SLOPE #6 REBAR ANCHOR z » <br /> 10 3/4 SKIRT. ° <br /> of ~ L TANK LEVEL SENSOR HOLDER a 3 ° <br /> F FILL (2) #6 REBAR ° <br /> �O2 - a ° laSLOPE CONCRETE AWAY FROM ALL3 -010'-4" 3'-O" V VAPOR RECOVERY O ° MANHOLE COVERS TO AVOID ° ° <br /> _=e-_=JI a a W o <br /> ACCUMULATION OF WATER ° <br /> 10 <br /> B10–DIESEL TANK MW MONITORING WELL <br /> 4 ' p Q <br /> 16'-4" S SPARE ° a ° ° a) O Q0 <br /> OVERALL TANK FARM 2" 4" 6" 6" #6 REBAR Z I�I <br /> 4S 4" SPARE SPAN Q I I I <br /> DCH O-DIESEL DISCHARGE ►� 4" CONCRETE APRON REINFORCEMENT ° J U w <br /> BILO <br /> V-6" 7 1/2" 1/2" (#4) REBAR © 12" ON CE ° ° Z z O� <br /> TANK FARM PLAN SINGLE - 10' DIA, BOTH WAYS, BOTTOM ONLY O <br /> ° Q <br /> Z <br /> 3/16)$ = 1 P—O" NOTE: DEADMEN MUST BE AT LEAST THE SAME LENGTH AS THE TANK. Q W LJ <br /> z <br /> A DEADMAN AND ANCHOR DETAIL ~ J o <br /> U IZ <br /> ° 0Z Q Q <br /> PP2 1 = 1 —0 OUTLINE OF CONCRETE APRON <br /> ° <br /> Q <br /> � W� U <br /> B CONCRETE TANK APRON REBAR DETAILS _ ^ <br /> �P2 1/4" = V-0" cc W Z Oz O <br /> 0 <br /> 8" REINFORCED CONCRETE Z Z <br /> IN PAVED AREA OPW MANHOLE COVER O <br /> 18"0 SECURITY MANHOLE OPW MANHOLE COVER <br /> FOR MONITORING WELL. SLOPE 4" REINFORCED CONCRETE OPW-6571 EVR–B164042SCO52P MULTI PORT MANHOLE <br /> CONCRETE TO DRAIN AWAYSLOPE TO DRAIN AWAY FROM OPW–MPWS33 WATER SHROUD <br /> IN LANDSCAPE AREA <br /> 1" IN 24" (TYP (1) PLACE) MANHOLE (TYP 1 " IN 24") 8" REINFORCED CONC. LL_ <br /> (SEE DETAIL 3/PP4) OPW MANHOLE COVER 18"0 MANHOLE FOR INTERSTITIAL IN PAVED AREA <br /> 3 TANK MONITOR <br /> 3 4" REINFORCED CONC. <br /> 180 MANHOLE FOR OBSERVATION WELL <br /> IS DCH L F V IN LANDSCAPE AREA <br /> / 7 \ <br /> =1 1=1 III=FTI=1 <br /> II=1TF-I I u=FTi=FTi- --1I=1Ti=1 F I 1=1Ti=1I=' <br /> -F F-FTF- F=FTF=FTF=F =FTF-FTF-F F-F F-F F-_ <br /> 00 <br /> -III III-III FII ' "III FFF-FFF FIF=' II FFF FFF-FFF III FFF III-li � <br /> III FII=FII-I� � � I FII-III IIF= I I I I I I I-FTi-I I FFF FFF FFF-FIF-I <br /> FFF-FTi-FTi FFF FFF=FFF-' II FII F�1=1I�-I _ F IFF Fu=FTi-li <br /> III-FTi-I I - I FII-FII=ITi I I FIF-FTF=FIF_ __ __ FFF FFF FTi-I i' <br /> -Ill illlllilll - = Illilllll lll- LL <br /> BACKFILL MATERM'E <br /> 2" LCX COAXIAL FIBERGLASS VENT PIPING <br /> — _ SLOPE MINIMUM 1/8" PER FOOT TO TOP OF <br /> 1 2 3 4 5 6 7 8 9 10 12 3 14 15 16 17 19 20 = TANK (1/4" PREFERRED) WITH A MINIMUM <br /> \ - p� D� {GI 18 _ BURY DEPTH ALLOWING 8 OF BACK FILL <br /> SANK #6 <br /> 20,000 GAL. _ I II D�I{4 = BETWEEN PIPING AND PAVING Q <br /> BIO–DIESEL \ _ <br /> _ _ SLOPE SIDE OF m <br /> II0 EXCAVATION AS REQUIRED <br /> II BRINE FILLED INTERSTITIAL _ 20,000 = BY SOIL CONDITIONS Z <br /> I 2" LCX COAXIAL FIBERGLASS - GALLON AND OSHA STANDARDS <br /> SLOPE SIDE OF = // BIO–DIESEL PIPE W/ SECONDARY = BIO–DIESEL = o J <br /> EXCAVATION AS REQUIRED CONTAINMENT TO INJECTION SUMP = 4" ALUMINUM DROP TUBE SEE v <br /> FILL/VENT DETAIL (TYP) <br /> BY SOIL CONDITIONS \ _ o m <br /> AND OSHA STANDARDS <br /> CONCRETE DEADMAN SUPPLIED WITH M o a <br /> TANK BY OWNER, INSTALLED BY CONTRACTOR N N <br /> LLL . LLL LLI L L L L L <br /> = rn <br /> O <br /> IIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII <br /> 01 <br /> AN <br /> SUOPPLED BY PNCRETE ILOT, <br /> 1,-42"(TYP) GENERAL NOTES <br /> o SEE DETAIL CAPACITY : 20,000 GALLONSQ o N <br /> SLOPE BOTTOM OF EXCAVATION 12" TO o I 4'-11" TYPE : DOUBLE WALL, UNDERGROUND BRINE FILLED I <br /> LOW POINT AT MONITORING WELL PIPE. I 5'-11" 5'-6" 2 6'-8" 5'-6" 5'-6" MATERIAL FIBERGLASS <br /> WELLS ARE AT LOW POINT OF EXCAVATION NOTE: STRAP LOCA IONS <br /> TANKS SHOWN ARE ATA BURIAL DEPTH EXTERIOR FIBERGLASS <br /> (TYP (1) PLACE) OF 5'-4". DEPTH OF TANKS VARY FROM 37'-82[ © FICOPYRIGHT,TRAVEL�PLAZABLIS"EDS <br /> CONFID <br /> SITE TO SITE. SEE TANK BURIAL DEPTH THIS DRAWINGISTIAL CONFIDENTIAL <br /> SCHEDULE (DWG. PPI A) FOR PROPER NO USE OR DISCLOSURE OF THIS DRAWING <br /> IS PERMITTED, EXCEPT AS EXPRESSLY <br /> BURIAL DEPTH AUTHORIZED BY FLYING J TRAVEL PLAZA <br /> 01 CROSS SECTIO THRU TANKS AT FILLS 02 20,000 GALLON BIO-DIESEL TANK SECTION <br /> �P2 1 /4" = V-0" PP2 1/4" = V-0" 20,000 GALLON UNDERGROUND FIBERGLASS sFr=Fr: <br /> DOUBLE WALL BIO-DIESEL/ B100 TANK <br /> 2 <br /> 15 <br /> L <br />