Laserfiche WebLink
Documents prepared by Core �QFESS�� <br /> OPW 61 10-48WT, 48"0 STEEL g g M.L <br /> States Engineering are to be used <br /> BOLT—DOWN MANHOLE COVER only for the specific project and CORE ST, <br /> NOTE 1" PAVEMENT "CROWN" ASSEMBLY WITH 10 3/4" SKIRT. specific use for which they are O <br /> SURROUNDING MANHOLE 3 intended. Any extension of use to ' Z <br /> other projects, by owner or any 34319 <br /> ° NEF WATERTIGHT LID AND 50" BASE other party, without the expressed, <br /> 0 0 ° �° written consent of Core States <br /> ADAPTER TO SLIP OVER XERXES EXISTING DIESEL TRUNK LINE Engineering is done at the user's <br /> REINFORCED CONC. ° ° ° ° ° p ° RISER. SUPPLIED BY OWNER (NEF), F�HAWCP <br /> SLAB �° ° INSTALLED BY CONTRACTOR. own risk. If used in a way other 1700 Industrial Drive,Suite B GROUP qTF SFO <br /> than that specifically intended, user Rogers,AR 72756 OFCAI <br /> EXTENSION IS BE ADJUSTED/ CUT will hold Core States Engineering Phone(479)986-4400 <br /> FOAM SPACER ALL ° ° AS REQUIRED BY CONTRACTOR PER harmless from all claims and losses. FAX(479)986-4401 <br /> AROUND SUMP SITE SPECIFIC GRADES. <br /> EXISTING DIESEL TANK STP ADD <br /> REINFORCED CONC. CHASE PIPING AND VACUUM <br /> SLAB THICKENED TO 1" ° LINE TO BIO—DIESEL SHED FOR <br /> BELOW SUMP TOP <br /> VACUUM SENSING SYSTEM <br /> NEW VEEDER—ROOT <br /> APPROVED WASHED 332310-003 VACUUM HOSE <br /> a STONE BACKFILL <br /> wo 2" LCX COAXIAL FIBERGLASS EXISTING DIESEL PUMP <br /> VACUUM CHASE PIPING <br /> _J XERXES DOUBLE WALLED — 50"0 x 36" HIGH <br /> FIBERGLASS CONTAINMENT SUMP EXTENSION o0 <br /> D SUPPLIED BY OWNER (XERXES), INSTALLED BY ° ° <br /> O <br /> a XERXES TO SUPPLY BOSTIK ADHESIVE REQUIRED BY CONTRACTOR PER SACTOR. EXTENSION IS BE ITE ADJUST/ AS <br /> SPECIFIC <br /> WITH EACH RISER. CONTRACTOR TO <br /> FOLLOW INSTRUCTIONS AS SUPPLIED BY GRADES. U <br /> XERXES TO MAKE SUMP WATER TIGHT. FBRAVO—BR—F-22—LS-2" LCX <br /> O o <br /> TERMINATION FITTING WITH <br /> TEST PORT FOR LCX PIPE <br /> XERXES DOUBLE WALLED — MULTISIDED 50"0 <br /> FIBERGLASS CONTAINMENT SUMP WITH 18" <br /> HIGH x 20" WIDE VERTICAL FLAT PANELS. <br /> XERXES TO SUPPLY BOSTIK ADHESIVE SUPPLIED BY OWNER (XERXES), INSTALLED <br /> WITH EACH RISER. CONTRACTOR TO BY CONTRACTOR. <br /> FOLLOW INSTRUCTIONS AS SUPPLIED BY <br /> XERXES TO MAKE SUMP WATER TIGHT. 50"0 FRP DOUBLE WALLED <br /> CONTAINMENT COLLAR <br /> NOTE: SUMP SHOWN IF FOR MAXIMUM 24" DOUBLE RING MANWAYDEPTH <br /> FROM BURIALFINISHEDOGRADEKTOTTOP OF 04 TYPICAL SUMP BURIAL DETAIL 05 EXISTING DIESEL TANK SUMP <br /> TANK. o <br /> �P3 3/4" = 1 '-0" PP3 3/4" = V-0" <br /> MORRISON 184 SERIES, 4" x 2" x 2" <br /> DOUBLE TAP BUSHING <br /> �APPROVED WASHED <br /> 2" BLACK STEEL. ELL. (TYP) STONE BACKFILL <br /> CONTRACTOR TO CAP 2" LCX COAXIAL <br /> 2" MORRISON MODEL 246 ADI FIBERGLASS SIPHON LINE <br /> CHECK VALVE (FOR FUTURE USE) <br /> 2" STAINLESS STEEL BALL VALVE FIBERGLASS 2" LCX COAXIAL <br /> ON PRODUCT LINE MUST HOLD SIPHON LINE AL DIESEL TANK APPROVED WASHED <br /> PRESSURE FOR TANKS TO BE STONE BACKFILL <br /> INDIVIDUALLY TESTED (FOR FUTURE USE) I� <br /> BRAVO—F-10—RR—D 1" CONDUIT 0 <br /> ELECTRICAL BULKHEAD FITTING, BRAVO—BR—F-20—FF—LCX-2" 24" FLANGED MANWAY3 Q <br /> CONDUIT TO J—BOX W/SEALOFF BULKHEAD FITTING AND SECONDARY U (-D <br /> FITTING (SEE ELECTRICAL SITE BOOT WITH TEST PORT FOR LCX PIPE Iz <br /> PLAN FOR CONTINUATION) 0 0 BRAVO—F-10—RR—D 1" CONDUIT 0 I I I <br /> NON—DISCRIMINATING SUMP 0 O 0 ELECTRICAL BULKHEAD FITTING, 0 0 0 0 <br /> CONDUIT TO J—BOX W SEALOFF BRAVO ELECTRICAL <br /> BULKHEAD <br /> 1" CONDUIT W <br /> Ln <br /> SENSOR IS TO BE PROGRAMMED o o / o o ELECTRICAL BULKHEAD FITTING, <br /> FITTING (SEE ELECTRICAL SITE <br /> FOR POSITIVE SHUT DOWN OF STP o PLAN FOR CONTINUATION) U <br /> 0 o CONDUIT TO J—BOX W/SEALOFF �� <br /> AND DISPENSER 0 0 0 FITTING (SEE ELECTRICAL SITE W <br /> PLAN FOR CONTINUATION) OPW 1TAG-7000 PRODUCT MARKER 0 � <br /> 0 _ <br /> 2" LCX COAXIAL FIBERGLASS 0 I 0 c VAPOR _ L\\L_I <br /> MARKER FOR MANHOLE COVER z <br /> BIO—DIESEL DISCHARGE LINE o / o OPW 1TAG—CV2 PRODUCT OPW 6521EVRB—SP 164048SCO52 C) / <br /> BRAVO—F-22—LS—D 2" BULKHEAD <br /> 0 o NON—DISCRIMINATING SUMP o o TANK PROBE — BIO—DIESEL 48" MULTI—PORT WITH 44" Z Q U O <br /> 0 SENSOR IS TO BE PROGRAMMED o o CLEARANCE WITH 15" SKIRT, (1) 5 ~ Q <br /> FITTING FOR LCX PIPING AND DOUBLE o FOR POSITIVE SHUT DOWN o 0 0 o OPW 106X-0200 PRODUCT MARKER GAL FILL SPILL BUCKET, (1) 5 GAL V <br /> WALLED SUMP SET IN CONCRETE — EXTRA BLENDED VAPOR SPILL BUCKET & (1) 8" (n <br /> � <br /> 2" BELL & MALE N.P.T. ADAPTER PRODUCT MARKER NUMBER SET IN GAUGE PORT Q Z QZ <br /> CONCRETE-1 PER TANK OPW 1711T-7085—EVR 3" VAPOR CAP 00 U <br /> VEEDER—ROOT 330020-536 2 TO 1 VEEDER—ROOT 330020-536 2 TO 1 CONCRETE PAVING — THICKENED AS OPW 61VSA-1020—EVR VAPOR SWIVEL � ' ` 0 z <br /> INPUT KIT— NONDISCRIMINATING INPUT KIT— NONDISCRIMINATING NEEDED v <br /> SUMP SENSOR 794380-208 AND SUMP SENSOR 794380-208 AND THE DOUBLE WALL PORTION OF THE W <br /> SINGLE POINT MINI—HYDROSTATIC SINGLE POINT MINI—HYDROSTATIC OPW 634TT-7085—EVR 4" TURBINE AND FILL SUMPS MUST U z O <br /> SENSOR 794380-304 (ABOVE) PLAN 2" BLACK STEEL UNION SENSOR 794380-304 (ABOVE) PLAN TOP—SEAL CAP, PRODUCT FILL a EXTEND TO THE BASE OF THE z 0— <br /> CONCRETE O <br /> OPW 107-0300 NAMEPLATE ° ° a <br /> NOTE: SUMP SHOWN IF FOR MINIMUM BURIAL DEPTH OF TANK AT HOLDER— CONTRACTOR TO MARKa G VEEDER—ROOT 330020-536 2 TO 1 > LC) <br /> 4'-11" FROM FINISHED GRADE TO TOP OF TANK. CONTRACTOR IS WITH TANK CAPACITY IN GALLONS a a a INPUT KIT— NONDISCRIMINATING <br /> RESPONSIBLE FOR FIELD VERIFYING TANK BURIAL DEPTH PRIOR TO ° a a SUMP SENSOR 794380-208 AND I ' <br /> CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR OPW 61SALP-1020—EVR 4" SWIVEL SINGLE POINT MINI—HYDROSTATIC L� <br /> CONFIRMING TANK PIT IS AT THE APPROPRIATE DEPTH FOR TANK ADAPTOR, PRODUCT FILL a SENSOR 794380-304 <br /> INSTALLATION, BUT NO LESS THAN 4'-11" OPW MPWS-33 WATERTIGHT SUMP as a <br /> COVER FOR MULTI—PORT XERXES MINIMUM 3" FOAM RING TO BE <br /> 48" SUMP WITH OPW SPILL BUCKET PLACED BETWEEN STEEL SKIRT AND <br /> MANWAY SUMP EXTENDING TO OUTER <br /> OTE: OTE: OPW 61JSK-4410 JACK SCREW WALL OF SUMP CONCRETE TO <br /> SEE OVERALL LAYOUT FOR DIRECTION PIPE SEE OVERALL LAYOUT FOR DIRECTION PIPE ASSEMBLY—DROP TUBE LOCKDOWN EXTEND 2' BELOW TOP OF COLLAR <br /> EXITS SUMPS AND EXTENSIONS EXITS SUMPS AND EXTENSIONS VEEDER—ROOT 330020-536 2 TO 1 BRINE FILLED MONITORING RESERVOIR <br /> VEEDER—ROOT 330020-536 2 TO 1 INPUT KIT— NONDISCRIMINATING OPW FSA-400 FACE SEAL ADAPTER, <br /> REFER TO DETAIL #2 THIS SHEET FOR INPUT KIT— NONDISCRIMINATING REFER TO DETAIL #2 THIS SHEET FOR SUMP SENSOR 794380-208 AND PRODUCT FILL SCHEDULE 40 BLACK IRON PIPE <br /> 4" <br /> SUMP AND MANHOLE DETAILS/SPECIFICATIONS SUMP SENSOR 794380-208 AND SUMP AND MANHOLE DETAILS/SPECIFICATIONS SINGLE POINT MINI—HYDROSTATIC VEEDER—ROOT 330020-536 2 TO 1 RISER 00 <br /> SINGLE POINT MINI—HYDROSTATIC SENSOR 794380-304 INPUT KIT — NONDISCRIMINATING <br /> SENSOR 794380-304 FINISHED GRADE SUMP SENSOR 794380-208 AND EXPLOSION PROOF JUNCTION BOX <br /> 0 0 ° ° ° FINISHED GRADE ° ° o o ° ° SINGLE POINT MINI—HYDROSTATIC <br /> w SENSOR 794380-304 CONDUIT FROM STP SUMP <br /> 0 ° ° ° ° ° ° ° ° CONTAINING SENSOR WIRING BACK <br /> ° °° ° ° ° °° ° BRAVO—F-10—RR—D 1" CONDUIT TO SITE MONITORING PANEL <br /> 0 ELECTRICAL BULKHEAD FITTING, <br /> CONDUIT TO J—BOX W/SEALOFF r BRAVO ELECTRICAL <br /> BULKHEAD <br /> 1" CONDUIT <br /> w FITTING (SEE ELECTRICAL SITE PLAN ELECTRICAL BULKHEAD FITTING, <br /> BRAVO—F-10—RR—D 1" CONDUIT 0'o CONDUIT TO J—BOX W/SEALOFF <br /> ELECTRICAL BULKHEAD FITTING, iD f APPROVED WASHED FOR CONTINUATION) FITTING (SEE ELECTRICAL SITE <br /> CONDUIT TO J—BOX W/SEALOFF Ln 0 n� STONE BACKFILL PLAN FOR CONTINUATION) <br /> BRINE FILLED MONITORING RESERVOIR J <br /> FITTING (SEE ELECTRICAL SITE z o 2 TO 1 INPUT KIT VEEDER R 5 APPROVED WASHED STONE BACKFILL <br /> CONDUIT FOR MANHOLE RESERVOIR <br /> PLAN FOR CONTINUATION) BLACZ S111Q,_ E PLn 330020-536 DOUBLE—WALL FILL/VENT TANK SENSOR AND SUMP SENSORtoI <br /> LL z 14 BRINE FILLED MONITORING RESERVOIR SUMP INSTALLED PER F— <br /> BRAVO—F-22—LS—D 2" BULKHEAD I 0�` BRAVO—F-10—RR—D 1" CONDUITI <br /> FITTING FOR LCX PIPING AND DOUBLE MORRISON MR-305—XPA-4EVR, MANUFACTURER'S SPECIFICATIONS 2" LCX COAXIAL FIBERGLASS VENT w <br /> ELECTRICAL BULKHEAD FITTING, <br /> w Y CONDUIT TO J—BOX W/SEALOFF 4" PROBE RISER CAP AND ADAPTOR PIPING SLOPE MINIMUM 1/8" PER � <br /> a <br /> WALLED SUMP KIT WITH CABLE GROMMET (TYP (1) PLACE) XERXES 48" DW CONTAINMENT FOOT <br /> az FITTING (SEE ELECTRICAL SITE o FILL/VENT SUMP — 48" U J <br /> Q~ PLAN FOR CONTINUATION) PHIL—TITE/FRANKLIN PT—MF4X4 DOUBLE—WALL CONTAINMENT SUMP, BRAVO FS32—TS—D 3"X2" TAPER w m <br /> 2" LCX COAXIAL FIBERGLASS 0 o RISER ADAPTOR (TYP (1) PLACE) 2 PIECE FLAT SIDED, OPEN TOP, BY SLIP DOUBLE WALL FITTING WITH p 1 <br /> BIO—DIESEL DISCHARGE LINE m NON—DISCRIMINATING SUMP SENSOR IS ° AND BRINE FITTINGS (VERIFY SECONDARY AND FLANGE TEST AND O Q <br /> TO BE PROGRAMMED FOR POSITIVE 4"0 BLACK STEEL RISER ) SCHRADER VALVE 1 <br /> 2 TO 1 INPUT KIT VEEDER ROOT D <br /> SHUT DOWN OF STP AND DISPENSER LENGTH REQUIRED <br /> PIPE THREADED BOTH ENDS <br /> VEEDER ROOT 794380-208 DRAIN PORT BALL VALVE PIPING N <br /> 330020-536 z w 2" LCX COAXIAL FIBERGLASS VENT 1 04 M <br /> 2" BELL & MALE N.P.T. ADAPTER APPROVED WASHED TANK SHELL TANK PROBE 4" SCHEDULE 40 BLACK IRON PIPE > o <br /> 2" STAINLESS STEEL BALL STONE BACKFILLS TOP OF TAN <br /> TOP OF TANK RISER SMITH FIBERGLASS RED THREAD 11A <br /> V 002020-191-7 2" BELL X MALE <br /> VALVE ON PRODUCT LINE MUST i <br /> HOLD PRESSURE FOR TANKS VEEDER—ROOT 330020-536 2 TO 1 THREADED ADAPTER Q <br /> TO BE INDIVIDUALLY TESTED 50"0 FRP DOUBLE WALLED INPUT KIT — NONDISCRIMINATING Q <br /> 50"0 DOUBLE WALLED FRP SINGLE POINT MINI—HYDROSTATIC N <br /> CONTAINMENT COLLAR SUMP SENSOR 794380-208 AND <br /> CONTAINMENT COLLAR SENSOR 794380-304 OPW 233-4420 TEE EXTRACTOR p I <br /> O r� <br /> DOUBLE—WALL <br /> X X2 <br /> DOUE—WALL FIBERGLASS TANK <br /> © COPYRIGHT, 2011 (UNPUBLISHED) <br /> TANK SHELL 2 ORRISON MODEL 246 ADI CHECK VALVE FLYING J TRAVEL PLAZA <br /> OPW 71 SO-410C 4" EVR ALUMINUM CONFIDENTIAL <br /> DROP TUBE WITH OVERFLOW THIS DRAWING IS CONFIDENTIAL <br /> NON—DISCRIMINATING SUMP SENSOR IS NO USE OR DISCLOSURE OF THIS DRAWING <br /> TO BE PROGRAMMED FOR POSITIVE PREVENTION VALVE IS PERMITTED, EXCEPT AS EXPRESSLY <br /> AUTHORIZED BY FLYING J TRAVEL PLAZA <br /> SHUT DOWN OF STP AND DISPENSER SECTION NOTE: DROP TUBE MUST BE SUBMERGED <br /> VEEDER ROOT 794380-208 STAGE I VAPOR RECOVERY SYSTEM SHALL BE INSTALLED <br /> 2" BLACK STEEL UNION AND TESTED PER CARB EXECUTIVE ORDER VR-102-1 WHEN LIQUID LEVEL IS 6" DEEP Sfr=T-. <br /> MORRISON 184 SERIES, 4" x 2" x 2" XERXES TANK FACTORY INSTALLED <br /> DOUBLE TAP BUSHING STRIKER PLATE AT EVERY TANK <br /> SECTION SECTION OPENING <br /> 01 BIO-DIESEL DISCHARGE SUMP 02 BIO-DIESEL TANK HEATER MANWAY 03 BIO-DIESEL TANK FILL/VENT MANWAY <br /> �P3 3/4" = V-0" BIO—DIESEL CHAMBER ONLY �P3 3/4" = 1 '-0" PP3 3/4" = 1 '-0" <br /> 15 <br /> L_ <br />