Laserfiche WebLink
Q oPaUW c �' SAN J O A Q U I N Environmental Health Department <br /> ` 4 -` COUNTY Linda Turkatte, REHS , Director <br /> , ; <br /> C P <br /> iF_o_ Greatness grows here . Kasey Foley, REHS, Assistant Director <br /> gta? <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco, REHS , RDI <br /> Michael Kith , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> March 21 , 2019 <br /> MARTY WEITHMAN <br /> SERVICE STATION SYSTEMS , INC . <br /> 680 QUINN AVE <br /> SAN JOSE , CA 95112 <br /> Re : MARCH LANE 76* SR0080049 <br /> 2701 W MARCH LN <br /> STOCKTON , CA 95219 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the application for <br /> a permit to replace the 87 and 91 octane direct bury spill containers with OPW 1 -2100 series spill containers and <br /> replace the 87 and 91 octane drop tubes with OPW 71 SO overfill prevention valves on the underground storage <br /> tank ( UST) system at the above noted address . The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209) 468-3440 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments) . <br /> Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut off. <br /> If ball floats are installed , verify that they do not interfere with the flapper valve operation . <br /> Complete and accurate drop tube calculations must be present onsite at the time of inspection . <br /> • Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test (or <br /> equivalent) . Proper drainage must also be verified . <br /> • Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to backfilling . <br /> Please be aware that the facility cannot receive fuel in the 87 and 91 - octane tank prior to the <br /> EHD inspection and approval . <br /> 4 . Since concrete will be broken near 87 and 91 - octane tanks, a secondary containment test must be <br /> performed on the 87 and 91 - octane tank once concrete is poured in accordance with the manufacturer's <br /> guidelines . <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www . sjcehd . com <br />