My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2022 1:50:11 PM
Creation date
3/25/2019 8:41:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANIL <br /> IFIED PROGRAM CONSOLIDATED FWq <br /> UNDERGROUND STORAGE TANK U Z/'�/rr K� <br /> OPERATING PERMIT APPLICATION-TANK INFORMAT N(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430 <br /> ❑ 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ® 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> ARCO 02186 <br /> BUSINESS SITE ADDRESS 103 CITY 104 <br /> 3212 N.CALIFORNIA ST. STOCKTON <br /> II.TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> 3 XERXES 1.A STAND-ALONE TANK <br /> C9 2.ONE IN A COMPARTMENTED UNIT <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 1999/07 12,000 2 <br /> III.TANK USE AND CONTENTS <br /> TANK USE E la.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED ® Ib.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 440b <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ L STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ® 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ I.SINGLE-WALLED ®2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION(23 CCR§2636(a)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ L STEEL E 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE E I.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ L STEEL 10 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464e1 <br /> VENT SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC E 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464n <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464g] <br /> VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC E 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464hl <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 90.NONE 4641• <br /> RISER PRIMARY CONTAINMENT ® I.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464kl <br /> FILL COMPONENTS INSTALLED E I.SPILL BUCKET ® 3.STRIKER PLATEBOTTOM PROTECTOR ® 4.CONTAINMENT SUMP 45la-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ L STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal requirements. <br /> APPLICANT SIGNATURE DATE 470. <br /> APPLICANT NAME(print) 471. APPLICANT TITLE 472. <br /> RICHARD GOSSETT ENVIRONMENTAL COMPLIANC IALIST <br /> Arco 02186,Belshire Environmental Services <br />
The URL can be used to link to this page
Your browser does not support the video tag.