My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0038674
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NORTHLAND
>
6103
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0038674
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 3:36:16 PM
Creation date
3/25/2019 9:50:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0038674
PE
4378
STREET_NUMBER
6103
Direction
E
STREET_NAME
NORTHLAND
STREET_TYPE
RD
City
MANTECA
Zip
95336-
APN
19712074
ENTERED_DATE
8/16/2018 12:00:00 AM
SITE_LOCATION
6103 E NORTHLAND RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\tsok
Supplemental fields
CYEAR
2018
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
August 25, 2021 Lab ID : STK2150883 <br /> San Joaquin Co.Environmental Health Dep Customer : 3-17919 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrate 300.0 (STK2150869-001) MSD mg/L 40.00 95.0% 85-119 <br /> MSRPD mg/L 10.00 0.2% <19 <br /> 300.0 08/03/21:212025MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L. 20.00 102% 90-110 <br /> CCB mg/L 0.085 0.5 <br /> CCV m 20.00 103% 90-110 <br /> Nitrate+Nitrite as N 300.0 08/03/21:208810MCA Blank mg/L ND <0.1 <br /> Nitrate Nitrogen 300.0 08/03/21:208810MCA Blank mg/L ND <0.1 <br /> Nitrite 300.0 08/03/21:208810MCA Blank mg/L ND <0.5 <br /> LCS mg/L 15.00 95.7% 90-110 <br /> MS mg/L 30.00 97.7% 74-126 <br /> (STK2150888-001) MSD mg/L 30.00 99.6% 74-126 <br /> MSRPD mg/L 10.00 1.9% 520 <br /> MS mg/L 30.00 99.5% 74-126 <br /> (STK2150869-001) MSD mg/L 30.00 100% 74-126 <br /> MSRPD mg/L 10.00 0.8% <20 <br /> 300.0 08/03/21:212025MCA CCB mg/L 0.000 0.5 <br /> CCV mg/L 15.00 99.8% 90-110 <br /> CCB mg/L 0.000 0.5 <br /> CCV mg/L 15.00 99.5% 90-110 <br /> Nitrite Nitrogen 300.0 08/03/21:208810MCA Blank m ND <0.2 <br /> Sulfate 300.0 08/03/21:208810MCA Blank mg/L ND <0.5 <br /> LCS mg/L 50.00 102% 90-110 <br /> MS mg/L 100.0 102% 82-124 <br /> (STK2150888-001) MSD mg/L 100.0 104% 82-124 <br /> MSRPD mg/L 10.00 1.7% 523 <br /> MS mg/L 100.0 101% 82-124 <br /> (STK2150869-001) MSD mg/L 100.0 102% 82-124 <br /> MSRPD mg/L 10.00 0.8% <23 <br /> 300.0 08/03/21:212025MCA CCB mg/L. 0.180 0.5 <br /> CCV mg/L 50.00 106% 90-110 <br /> CCB mg/L 0.155 0.5 <br /> CCV mg/L 50.00 106% 90-110 <br /> MBAs 5540C 08/04/21:211422JBA CCB mg/L. -0.0393 0.25 <br /> CCV mg/L 1.000 96.6% 90-110 <br /> CCB mg/L -0.0185 0.25 <br /> CCV I mgfL 1.000 97.8% 1 90-110 <br /> MBAs Extraction 5540C 08/03/21:209066JBA Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 96.6% 86-114 <br /> BS mg/L 0.5000 95.5% 86-114 <br /> BSD mg/L 0.5000 96.7% 86-114 <br /> BSRPD mg/L 0.5000 0.0063 <0.1 <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.