My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
INSTALL 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 2:07:38 PM
Creation date
3/25/2019 4:40:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1999
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r >i� �� <br /> Specifying Accessory Components T s ? = zK <br /> Flexible Isolation Tube 3 x 2 Reducer Seal <br /> If dielectric isolation of the flexible If the Flexible Isolation Tube Is <br /> connectors are required order one required to seal,at its lower end, <br /> Flexible Isolation Tube.for each directly to 2' pipe instead of 3' <br /> pipe entry. This isolation tube pipe,then this rubber reducer seal <br /> comes equipped to attach directly is required to make this transition. <br /> to the base of the Pipe Entry Boot This rubber seal can be used In <br /> at one end and connect to 3-pipe place of a Pipe Entry Boot when <br /> at the other end. Incudes a 30- circumstances require 2' rigid <br /> rubber lube and two band clamps. pipe entering directly into the pan. <br /> Also available in a 42' long tube <br /> which has its own air valve stem. <br /> Conduit Entry Seals Drain Fitting Kit <br /> These rubber seals are used to Should the pan be required to be <br /> >. <br /> seal conduit which enters the drained into the secondary piping <br /> bottom of the pan through the system then the Drain Fitting Kit <br /> conduit entry cuffs. Specify the should be installed. This kit <br /> size of the conduit when order. includes all the necessary ?<; <br /> ing these rubber seals. There _. _ components to connect the pan to :; z@ <br /> are three sizes available: ithe Flexible Isoaltion Tube with a <br /> 1/2'nylon drain tube. The Petr0- <br /> 1/2': <br /> -1/2': CES-1550 Trip Kit can not be used in this <br /> 3/4": CES-1575 Application. < <br /> 1": CES-1510 <br /> Flexible Boot Adapter Stage II Entry Boot <br /> In the event that a Flexible Entry The Stage 11 Entry Boot used for •'` <br /> Boot is required to be installed in "` pans which provide a stage II �;,•,..c> ;N :;;;;. <br /> the bottom ofAhe pan, to seal a - entry cuff in the location of the ` <br /> stege II vapor recovery pipe entry, "^ stage It pipe entry. The assembly <br /> . . <br /> then this adapter permits the ^<?#p:i ?:: includes a 7-long rubber entry <br /> isolation tube to be connected to boot with air valve stem,a 3-to 1- <br /> the outside base of the Flexible cs.:>::z':i rubber reducer and and two band <br /> Envy Boot. For more information clamps. This boot is permits a <br /> about this application contact your `?': 's`':# Flexible Isolation Tube to be <br /> local distributor or Environ. ? zr connected to it's base for isoiation <br /> ` '•%'?`r of a flexible connector. <br /> Petro-Trip Kit Trip Sensor Switch <br /> Should automatic shut-of of the Should automatic shut-off of the <br /> shear valves be required, in the electronic dispenser be required <br /> event of product collecting in the in the event of a product leak into <br /> base of the pan, then specify the the pan, the Trip Sensor Switch <br /> Petro-Trip Kit. This device is a <br /> should be ordered. This switch is <br /> spring loaded sensor which willactivated when the Petro-Tnp . . <br /> engage and trip the shear valve engages and will automatically cut <br /> lusable link in the presence of the power to the dispenser. <br /> gasoline in the pans collection <br /> well. Kit accommodates up to four <br /> shear valves. <br /> Sensor Stabilizer lube Remote Draining System <br /> If a electronic leak detection A remote draining system Is >.:•:: <br /> sensor is to be installed inside the available for the dispenser pans ry%:��%�r:$i��;::>:::%•`:::y:E:E;•i <br /> Pan for monitoring the Sensor which will drain any leaking `•x•;>;•.i.>.;:.;:;:::;•.:;.:.•,;:.: <br /> Stabilizer Tube will secure the product away from the dispenser <br /> sensor in an upright position to a remote collection sump. This <br /> directly over the collection well. system has a number of <br /> The sensor should be no larger components, such as, a primary <br /> than 2.125' in dia.. The tube is and secondary drain line, drain <br /> made of stainless areal wire mesh fittings,tee fittings and a collection <br /> and comes with a mounting sump,which are all described in <br /> bracket to be secured to the pan's more detail on page 9. <br /> stabilizer bar. <br /> 2 <br />