Laserfiche WebLink
DAY OR NIGHT <br /> TELEPHONE C ERTIFI C A T E IVO, 2 9 71 <br /> (510) 235-1393 CERTIFIED SERVICES COMPA14Y CUSTOMER <br /> 255 Parr Boulevard , Richmond, California 94801 <br /> JOB NO. <br /> HENDERSON CONST. <br /> FOR: ECOLOGY CONTROL INDTANK NO. 26884 <br /> LOCATION: RICHMOND,CA 7/17lt?0 12'99:!2 <br /> DATE: TIME:— <br /> TEST METHOD VISUAL GASTECH11314SMPN <br /> LAST PRODUCT UO <br /> This is to certify that I have personally determined that this tank is in accordance with the American <br /> Petroleum Institute and have found the condition to be in accordance with Its assigned designation, <br /> This certificate is based on conditions existing at the time the inspection herein set forth was <br /> completed and is issued subject to compliance with all qualifications and instructions. <br /> TANK SIZE 741 LF GALLON TANK SAFE FOR FIRE <br /> CONDITION <br /> REMARKS: OXYGEN 20.9%LOWER EXPLOSIVE LIMIT LESS THAN 0.1%ECOLOGY CONTROL INDUSTRIES <br /> HERBY CERTIFIES THAT THE ABOVE NUMBERED TANK HAS BEEN CUT OPEN,PROCESSED, <br /> AND THEREFORE DESTROYED AT OUR PERMITTED HAZARDOUS WASTE FACILITY. <br /> F <br /> the event of any physical or atmospheric changes affecting the gas-free conditions of the above tanks, or If In any doubt, <br /> mediately stop all hot work and contact the undersigned. This permit Is valid for 24 hours If no physical or atmospheric <br /> anges occur. <br /> TANDARD SAFETY DESIGNATION <br /> SAFE FOR MEN: Means that in the compartment or space eo designated (a) The oxygen content of the atmosphere is at least <br /> 18.5 percent by volume; and that (b) Toxic materials In the atmosphere are within permissable concentrations; and (c) in the <br /> judgment of the Inspector, the residues are not Capable of producing toxic materials under existing atmospheric conditions <br /> while maintained as directed on the Inspector's certificate. <br /> SAFE FOR FIRE: Means that In the compartment so designated (a) The concentration of flammable materials In the <br /> atmosphere is below 10 percent of the lower explosive limit; and that (b) In the judgment of the Inspector, the residues are <br /> not capable of producing a higher concentration that permitted under existing atmospheric conditions in the presence of fire <br /> and while maintained as directed on the Inspector's certificate, and further, (c) All adjacent spaces have either been cleaned <br /> sufficiently to prevent the spread of fire, are satisfactorily inerted, or in the case of fuel tanks, have been treated as deemed <br /> necessary by the Inspector. <br /> The undersign representative acknowledges receipt of this certificate and understands he C nditions an I ItAtlona under <br /> whicq i is Iced.• � tt <br /> p REPR NT TIVE TITLE ,�---f, <br /> INSPECTOR d <br />