GENERAL NOTES1. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDINGSHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKSSITE SURVEYOR AND BECOME THOROUGHLY FAMILIAR WITH THE SITECONDITIONS PRIOR TO BIDDING OR CONSTRUCTION.2. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKSCONSTRUCTION MANAGER TO RESOLVE ANY CHANGES, OMISSIONSOR PLAN DISCREPANCIES PRIOR TO BIDDING OR CONSTRUCTION.3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITHLOCAL, COUNTY, STATE AND FEDERAL CODES AND ORDINANCES.4. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALLUTILITIES.5. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDINGCLEARANCES REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKSCONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TOPROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACEOF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALLDIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOTSCALE DRAWINGS.6. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTINGWALLS, FLOORS, CEILINGS, OR OTHER SURFACES IDENTIFIED TOREMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THEWORK.7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAININGPERMITS FOR FIRE PROTECTION, PLUMBING, MECHANICAL, ANDELECTRICAL SYSTEMS PRIOR TO INSTALLATION OF SUCH SYSTEMS.8. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TONOTE AND DOCUMENT ALL CHANGES DURING CONSTRUCTION. THISSET SHALL BE A PART OF THE GENERAL CONTRACTOR’S “STORECLOSE-OUT PACKAGE” AS DESCRIBED IN THE CONSTRUCTIONMANAGEMENT AGREEMENT.9. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATINGDELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRDPARTY LOGISTICS DISTRIBUTION SERVICES AND VENDOR DIRECTSHIPMENTS. REFER TO CONSTRUCTION MANAGEMENT AGREEMENTFOR METHODS AND LEAD TIMES.10. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS ANDEQUIPMENT IS IDENTIFIED IN THE DRAWING SCHEDULE SHEETSUNDER THE COLUMN LABELED "RESPONSIBILITY".11. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEANTO PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE,BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS,AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONINSTALLATION, UNLESS OTHERWISE NOTED.12. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKSDESIGN MANAGER.13. REFER TO ITEM CUTSHEETS FOR ADDITIONAL INFORMATION.MAILINGADDRESS:PROGRAMMANAGER:STOREDESIGNER:CONSTRUCTIONMANAGER:LANDLORD:ARCHITECT OFRECORD:M/E/PCONSULTANT OFRECORD:STARBUCKS COFFEE COMPANY2401 UTAH AVENUE SOUTHMS STOP: S-SD10SEATTLE, WASHINGTON 98134(206) 318-1575CHIEN-HO LINSTARBUCKS COFFEE COMPANY17700 NEWHOPE ST., #200FOUNTAIN VALLEY, CA 92708P: (714) 885-3964F: (714) 885-3983E: CHLIN@STARBUCKS.COMMICHELLE DARMOKOSTARBUCKS COFFEE COMPANY17700 NEWHOPE ST., #200FOUNTAIN VALLEY, CA 92708P: (714) 885-3909F: (714) 885-3983E: MDARMOKO@STARBUCKS.COMKATE ZOVICHSTARBUCKS COFFEE COMPANY17700 NEWHOPE ST., #200FOUNTAIN VALLEY, CA 92708P: (714) 885-3935F: (714) 885-3983E: KZOVICH@STARBUCKS.COMGAVIN REID610 NEWPORT CENTER DR.NEWPORT BEACH, CA 92660P: (949) 800-8341E: GAVIN@FRONTIERREI.COMCHRIS LEEMCG ARCHITECTURE111 PACIFICA, SUITE 280IRVINE, CA 92618P: (949) 553-1117F: (949) 474-7056E: CLEE@MCGARCHITECTURE.COMMIKE KILGORESCHACKEL ENGINEERS3035 SOUTH 72ND STREETOMAHA, NE 68124P: (402) 391-7680D: (531) 329-6317E: MKILGORE@SCHNACKEL.COMPROJECT CONTACTSINDEX OF SHEETSROOM SCHEDULESCOPE OF WORKTENANT IMPROVEMENT OF LANDLORD DELIVERED SHELL FOR ASTARBUCKS COFFEE COMPANY.WORK SHALL INCLUDE INTERIOR PARTITIONS, INTERIOR FINISHES,EQUIPMENT, LIGHTING, HVAC, AND RELATED.NO SITE WORK INCLUDED.CODE AUTHORITIE(S):BUILDING CODE:PLUMBING CODE:MECHANICAL CODE:ELECTRICAL CODE:ENERGY CODE:FIRE CODE:SPRINKLERED:HEALTH CODE:ACCESSIBILITY CODE:LOCAL CODE(S):PROJECT DESCRIPTION:ZONING:TYPE OF USE:TYPE OF OCCUPANCY:TYPE OF CONSTRUCTION:OCCUPANCY LOAD:BEVERAGE PREPRETAIL / SALESGENERAL SEATINGFIXED SEATINGWORKROOMTOTAL INTERIOR OCCUPANT LOAD: 41TOTAL GROSS SQUARE FOOTAGE: 1,851EXITS:EXIT WIDTH REQUIRED:SEATING SUMMARY:SITE AND OCCUPANCYSTATE OF CALIFORNIA2016 CALIFORNIA BUILDING CODE2016 CALIFORNIA PLUMBING CODE2016 CALIFORNIA MECHNICAL CODE2016 CALIFORNIA ELECTRICAL CODE2016 CALIFORNIA ENERGY CODE2016 CALIFORNIA FIRE CODENOCALIFORNIA RETAIL FOOD CODE2016 CALIFORNIA BUILDING CODE / ADAAPPLICABLE ORDINANCES AND MUNICIPALCODES OF THE CITY OF STOCKTONAPPLICABLE ORDINANCES OF THE COUNTY OFSAN JOAQUIN, ENVIRONMENTAL HEALTHSERVICESCOMMERCIAL REMODEL OF AN EXISTINGTENANT IMPROVEMENTCOMMERCIALRETAIL SALES AND SERVICESB, COFFEE SHOPV-B448 SF / 200 = 3289 SF / 60 = 5453 SF / 15 = 31NA322 SF / 300 = 21-49 OCC = 1 EXIT REQ'D; 1 EXITS PROVIDED41 OCCUPANTS X 0.2 = 8.2"72" PROVIDED(P) INDOOR SEATING: 24 SEATS / 4 TABLESACCESSIBLE SEATS REQ'D: 2 (24 X 0.05 = 1.2)ACCESSIBLE SEATS PROVIDED: 4(P) OUTDOOR SEATING: 8 SEATS / 4 TABLESACCESSIBLE SEATS REQ'D: 1 (8 X 0.05 = .4)ACCESSIBLE SEATS PROVIDED: 1VICINITY PLANAERIAL MAPASSESSOR'S PARCEL NUMBER: 139-060-32LEGAL DESCRIPTION79 SFSEATING374 SFSEATING289 SFRETAIL/SALES448 SFBEVERAGEPREP322 SFWORKROOM2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575SHEET NUMBER:SHEET TITLE:SCALE: AS SHOWNSTORE #:PROFILE TYPE:PROJECT #:ISSUE DATE:PROGRAM MANAGER:STORE DESIGNER:CHECKED BY:PROJECT NAME:PROJECT ADDRESS:STARBUCKS COFFEECOMPANYRLEED AP:© 2017 STARBUCKS COFFEE COMPANY®111 Pacifica, Suite 280, Irvine, CA 92618P: 949.553.1117 F: 949.474.7056San FranciscoClevelandDenverIrvineARCHITECT OF RECORDARCHITECT STAMP2017MCG PROJ. MANAGER:MCG PROJ. SPECIALIST:MCG PROJECT #:THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BEREPRODUCED (IN WHOLE OR IN PART), SHAREDWITH THIRD PARTIES OR USED IN ANY MANNERON OTHER PROJECTS OR EXTENSIONS TO THISPROJECT WITHOUT THE PRIOR WRITTENCONSENT OF STARBUCKS CORPORATION.THESE DRAWINGS AND SPECIFICATIONS AREINTENDED TO EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH ISSUBJECT TO CHANGE AT ANYTIME) AND DONOT REFLECT ACTUAL SITE CONDITIONS.NEITHER PARTY SHALL HAVE ANY OBLIGATIONNOR LIABILITY TO THE OTHER (EXCEPT STATEDABOVE) UNTIL A WRITTEN AGREEMENT ISFULLY EXECUTED BY BOTH PARTIES.mcg architecture8/30/2017 5:42:29 PMJ:\2016 Projects\0-Starbucks\16514_SBX-6970_El Dorado & Fremont_Stockton_CA (NS-RELO)\02-Arch\3-CD\1-Revit Files\16514_SBX-6970_El Dorado & Fremont_Stockton.rvtG-000121295-04208/18/17ELDORADO &FREMONT510NELDORADOSTREETSTOCKTON, CA 95202SANJOAQUIN COUNTYCORE6970CH. LINM. DARMOKOGENERAL INFORMATIONC. LEEG. MONTALVO16514NAME AREABEVERAGE PREP 448 SFRETAIL/SALES 289 SFSEATING 453 SFWORKROOM 322 SFGrand total 1513 SFScale:1/8" = 1'-0"OCCUPANCY DIAGRAMSHEET SHEET TITLE01 GeneralG-0001 GENERAL INFORMATIONG-0002 COMPOSITE PLANG-0003 ACCESSIBILITY NOTESG-0004 ACCESSIBILITY NOTESG-0006 PRE-APPROVED CONST. MATERIALSG-0007 PRE-APPROVED CONST. MATERIALSG-0010 OUTLINE SPECIFICATIONSG-0011 OUTLINE SPECIFICATIONSG-0012 OUTLINE SPECIFICATIONSG-0013 OUTLINE SPECIFICATIONS05 ArchitecturalA-0001 ARCHITECTURAL INFORMATIONA-1001 ARCHITECTURAL SITE PLANA-2001 EXTERIOR ELEVATIONSA-2002 EXTERIOR ELEVATIONSA-5003 DRIVE THRU & SITE DETAILSA-5004 DRIVE THRU & SITE DETAILS06 InteriorsI-1103 FLOOR PLANI-1104 PENETRATION PLANI-1105 FF AND E PLANI-1106 CASEWORK PLANI-1107 REFLECTED CEILING PLANI-1107.1 ENLARGED RCPI-1108 RCP LIGHTING DIMENSION PLANI-1108.1 ENLARGED LIGHTING DIMENSION PLANI-1109 FLOOR FINISH PLANI-1110 WALL FINISH PLANI-2101 INTERIOR ELEVATIONSI-2102 INTERIOR ELEVATIONSI-4101 ENLARGED RESTROOM PLANI-4102 ENLARGED RESTROOM ELEVATIONSI-5001 CONSTRUCTION DETAILSI-5002 CASEWORK DETAILSI-5003 CASEWORK DETAILSI-5004 CASEWORK DETAILSI-5005 CASEWORK DETAILSI-5007 WALL OF CHILL DETAILSI-5008 WALL FINISH DETAILSI-5009 FLOOR FINISH DETAILSI-5010 CEILING DETAILSI-6001 SCHEDULESI-6002 SCHEDULES07 PlumbingP-0001 PLUMBING SPECIFICATIONSP-0002 PLUMBING SPECIFICATIONSP-0003 PLUMBING SPECIFICATIONSP-0004 PLUMBING SPECIFICATIONSP-1000 PLUMBING SCHEDULESP-1101 PLUMBING SUPPLY PLANP-1102 PLUMBING WASTE AND VENT PLANP-1103 PLUMBING DETAILSP-1104 PLUMBING DETAILSP-1105 PLUMBING RISER DIAGRAMSP-7001 T24 ENERGY CALCULATIONS08 MechanicalM-0001 HVAC SCHEDULES AND SPECIFICATIONSM-1101 HVAC ROOF PLANM-1102 HVAC PLANM-1103 HVAC DETAILSM-1104 HVAC DETAILSM-1105 MECHANICAL DETAILSM-5001 HVAC SPECIFICATIONSM-5002 HVAC SPECIFICATIONS09 ElectricalE-0001 ELECTRICAL SPECIFICATIONSE-0002 ELECTRICAL SPECIFICATIONSE-0003 ELECTRICAL NOTES AND LEGENDSE-1100 ELECTRICAL SITE PLANE-1101 POWER AND SYSTEMS PLANE-1102 ENLARGED ENGINE POWER/SYSTEMS PLANE-1103 LIGHTING PLANE-1104 LUTRON CONTROL DIAGRAMSE-1105 LUTRON CONTROL DIAGRAMSE-5001 ELECTRICAL DETAILSE-6001 PANEL SCHEDULES AND ONE-LINE DIAGRAME-7001 T24 ENERGY CALCULATIONSE-7002 T24 ENERGY CALCULATIONSRevision ScheduleRev Date By DescriptionSan Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 9/11/17Nov 09, 2017 Leyna Huynh
|