Laserfiche WebLink
FLOOR PLAN KEYNOTESFLOOR SINK. SEE CUTSHEETS FOR COMPONENTSPECIFICATIONS AND CUTOUT REQUIREMENTS.FLOOR DRAIN. SEE CUTSHEETS FOR COMPONENTSPECIFICATIONS AND CUTOUT REQUIREMENTS.GC TO PROVIDE AND INSTALL 4" CONCRETE CURB ATFOODCASE, CURB NOT TO EXCEED FOOTPRINT OF CASE.CURB TO RECEIVE TILE BASE.GC TO PROVIDE AND INSTALL 6" CONCRETE CURB ATSAFE TO BE FLUSH WITH SAFE CABINET, NOT TOE KICK.CURB TO RECEIVE TILE BASE.10" CONCRETE SLAB TO BE SAME HEIGHT AS MOP SINK.REFER TO DETAIL SHEETS.DIMENSION DATUM POINT.GC TO POST SIGN THAT READS "THIS DOOR TO REMAINUNLOCKED DURING BUSINESS HOURS."GC TO PROVIDE & INSTALL METAL STRAPPING FORSTAINLESS STEEL BACKSPLASH.GC TO PROVIDE FRY REGLET AT CORNERS. REFER TODETAIL SHEETS.A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS ANDNOTIFY STARBUCKS CONSTRUCTION MANAGER OF ANYDISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONSTO BE TAKEN FROM DESIGNATED DATUM POINT.B. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDSREQUIRED AMERICAN’S WITH DISABILITY ACT (ADA) MAXIMUMHEIGHT OF 1/2", REMOVE & REPLACE WITH ACCESSIBLETHRESHOLD. RAISED THRESHOLDS & FLOOR LEVELCHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED WITHA SLOPE NO GREATER THAN 1:12.C. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOODSTUD BLOCKING, OR EQUIVALENT TO SUPPORT ANY WALLATTACHMENT AND/OR SIGNAGE.D. ALL DOORS TO PROVIDE 3’-6” (900MM) MINIMUM CLEAROPENING WHEN OPENED TO 90 DEGREE POSITION UNLESSOTHERWISE NOTED.E. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEETSTARBUCKS AND/OR CODE REQUIREMENTS.F. VERIFY SPECIFIED DOOR(S) WILL ACCEPT FALCON LOCKCORE(S). FALCON LOCK CORE SUPPLY IS BY STARBUCKS.COORDINATE ORDER & DELIVERY FROM LOCKET (800-887-4307) PROVIDING A MINIMUM SCHEDULING NOTICE OF 4WEEKS. FALCON LOCK CORE(S) FINISH TO MATCH LOCKSETFINISH. FALCON LOCK CORE(S) TO BE INSTALLED ON THE DAYOF TURNOVER.G. INSTALL 1/4" (6MM) GREEN BOARD ON BACKBAR WALL PERSPECIFICATION.H. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS SHOWN ORNOTED OTHERWISE.I. SEE SHEET A-6001 FOR EXTERIOR DOOR AND WINDOWSCHEDULES. SEE SHEET A-1103 FOR TAGGED LOCATIONS OFEXTERIOR WINDOWS AND DOORS.J. STARBUCKS VENDOR TO PROVIDE HARDWARE SCHEDULEAND HARDWARE COMPONENTS. GC TO INSTALL.K. USE EXISTING ELECTRICAL AND PLUMBING STUB-UPPENETRATIONS.L. USE EXISTING PENETRATIONS FOR PLUMBING ON THEBACKBAR WALL, WHERE APPLICABLE.M. PATCH AND REPAIR WALLS AS NECESSARY TO PROVIDE AFINISHED READY SURFACE.FLOOR PLAN GENERAL NOTES12345672X6 OR 2X8 SOLID BLOCKING AT ALL WALL HUNGFIXTURES. CONTRACTOR WILL NOT SUBSTITUTESHEET METAL FOR SOLID BLOCKING.GC RESPONSIBLE TO VERIFY EXISTINGSLAB CONDITIONS PRIOR TO ANY SAWCUTOR TRENCH WORK.ALL DIMENSIONS ARE TO FINISH FACE OF WALLS.N. LANDLORD TO PROVIDE DOOR HARDWARE PER STARBUCKSSPECIFICATIONS.O. GC TO PROVIDE WATER RESISTANT GYP. AT RESTROOM &BACKBAR WALLS.89NEW FULL HEIGHT WALLEXISTING WALLINTERIOR WALL LEGENDNEW PARTITION WALLTO 6" ABOVE CEILING20 GA 3-5/8" METAL STUDS@16" OC WITH 5/8" FIRERATED DRYWALL ON ONE OR BOTH SIDES TO MINIMUMOF 6" ABOVE CEILING GRID. DRYWALL SCREWS@12" OC.45 DEGREES. METAL STUD REINFORCEMENT @ 48" OCABOVE CEILING LINE TO STRUCTURE ABOVE.35"NEW PLUMBING WALLTO 6" ABOVE CEILING20 GA 6" METAL STUDS @ 16" OC WITH 5/8" MOISTURERESISTANT FIRE RATED DRYWALL ON BOTH SIDES TOMINIMUM 6" ABOVE CEILING. SECURE MOISTURERESISTANT FIRE RATED DRYWALL BOARD TO STUDSWITH DRYWALL SCREWS AT 10" OC AT PANEL EDGESAND 12" OC AT INTERMEDIATE SUPPORTS. 45 DEGREEMETAL STUD REINFORCEMENT @ 48" OC ABOVE CEILINGLINE TO STRUCTURE ABOVE.771/4"NEW FURRED PLUMBING WALLTO 6" ABOVE CEILING20 GA 6" METAL STUDS@16"OCWITH5/8"MOISTURERESISTANT FIRE RATED DRYWALL TO CEILING. SECUREMOISTURE RESISTANT FIRE RATED DRYWALL BOARD TOSTUDS WITH DRYWALL SCREWS AT 10" OC AT PANELEDGES AND 12" OC AT INTERMEDIATE SUPPORTS. 45DEGREE METAL STUD REINFORCEMENT @ 48" OC ABOVECEILING LINE TO STRUCTURE ABOVE.8EXISTING WALL61/2"NEW PARTITION WALLTO 6" ABOVE CEILING WITH MOISTURERESISTANT DRYWALL AT RESTROOM /BACKBAR / WALL OF CHILL SIDE ONLY20 GA 3-5/8" METAL STUDS @ 16" OC TO STRUCTUREABOVE WITH 5/8" MOISTURE RESISTANT FIRE RATEDDRYWALL ON RESTROOM SIDE TO CEILING AND 5/8" FIRERATED DRYWALL ON OTHER SIDE TO MINIMUM 6" ABOVECEILING GRID. SECURE MOISTURE RESISTANT FIRE RATEDDRYWALL BOARD TO STUDS WITH DRYWALL SCREWS AT10" OC AT PANEL EDGES AND 12" OC AT INTERMEDIATESUPPORTS.105"NEW PARTITION WALLTO 6" ABOVE CEILING WITH MOISTURERESISTANT DRYWALL AT BOTH SIDES20 GA 3-5/8" METAL STUDS@16" OC TO 9'-0" AFF WITH 5/8"MOISTURE RESISTANT FIRE RATED DRYWALL ON BOTHSIDES. SECURE MOISTURE RESISTANT FIRE RATEDDRYWALL BOARD TO STUDS WITH DRYWALL SCREWS AT10" OC AT PANEL EDGES AND 12" OC AT INTERMEDIATESUPPORTS. 45 DEGREES METAL STUD REINFORCEMENT @48" OC ABOVE CEILING LINE TO STRUCTURE ABOVE.115"EXISTING WALL1WALL TYPE LEGENDNEW PARTITION WALLTO STRUCTURE WITH MOISTURERESISTANT DRYWALL AT RESTROOM /BACKBAR / WALL OF CHILL SIDE ONLY)20 GA 3-5/8" METAL STUDS@16" OC TO STRUCTURE ABOVEWITH 5/8" MOISTURE RESISTANT FIRE RATED DRYWALL ONRESTROOM SIDE TO CEILING AND 5/8" FIRE RATED DRYWALLON OTHER SIDE TO STRUCTURE ABOVE. SECURE MOISTURERESISTANT FIRE RATED DRYWALL BOARD TO STUDS WITHDRYWALL SCREWS AT 10" OC AT PANEL EDGES AND 12" OCAT INTERMEDIATE SUPPORTS.95"WALL BLOCKING KEYSYMBOLITEMREMARKSWEIGHTHEIGHT AFFAPPROX WIDTHWORKROOM HAND SINKSHELVES ABOVE 3-COMP SINKSHELVES AND DATA RACKAT MANAGER'S DESKRESTROOM GRAB BARSRESTROOM HAND SINKUPPER STORAGESHELVES AT BACKBARGC TO PROVIDE BLOCKING AS REQ'D FORUPPER STORAGE SHELVES AT BACKBAR.125 LBS200 LBS300 LBS250 LBS3'-0" TO 3'-4"5'-8" TO 6'-0"1/2" AC PLYWOOD2'-6" TO 3'-0"2'-6" BEHIND SINK8'-0" CENTEREDABOVE 3-COMP SINK7'-0" CENTERED ABOVEMANAGER'S DESK ANDDATA RACK5'-0" AROUND WCS200 LBS3'-0" TO 3'-4"2'-6" BEHIND SINKDRIVE THRUCOMMUNICATIONS EQUIP.100 LBS4'-0" TO 6'-6"4'-0" BEHIND POS ANDBARISTA AT DT WINDOWWATER CHILLER WALLMOUNTED BLOCKINGGC TO PROVIDE BLOCKING AS REQ'DFOR 50LB LIVE LOAD.ABCD300 LBS 6'-1" TO 7'-10"EXTENT OF SHELVESDIAPER CHANGING STATION 200 LBS4'-0" TO 6'-6"EFGHJ6'-4" TO 8'-0"3'-0"30 LBSFLOOR SINKFLOOR PENETRATIONRESTROOM FLOOR DRAINFLOOR PLAN SYMBOL LEGENDCAFE/SEATINGSALESWORKROOMDRIVE-THRUBACKBARUNISEXRESTROOMARESTROOMVESTIBULEADJACENTTENANT(N.I.C.)UNISEXRESTROOM B1' - 5 1/4"1' - 5 1/4"10' - 6"15' - 10"25' - 5"37' - 1 1/2"41' - 3"10"9' - 0"10' - 1"4' - 1"8' - 7 1/2"14' - 4"19' - 2"23' - 1"24' - 3"3' - 4 1/2"6' - 4 1/2"7' - 0 1/2"15' - 8 1/2"18' - 1 1/2"19' - 9 1/2"20' - 0"23' - 0"11111110811311711711103111TYP.23456678899999999999ABBCDDDDEFGHEJJ71079' - 0"9102' - 8 1/4"5' - 6 1/4"101010ALIGNALIGNALIGN2401 UTAH AVENUE SOUTHSEATTLE, WASHINGTON 98134(206) 318-1575SHEET NUMBER:SHEET TITLE:SCALE: AS SHOWNSTORE #:PROFILE TYPE:PROJECT #:ISSUE DATE:PROGRAM MANAGER:STORE DESIGNER:CHECKED BY:PROJECT NAME:PROJECT ADDRESS:STARBUCKS COFFEECOMPANYRLEED AP:© 2017 STARBUCKS COFFEE COMPANY®111 Pacifica, Suite 280, Irvine, CA 92618P: 949.553.1117 F: 949.474.7056San FranciscoClevelandDenverIrvineARCHITECT OF RECORDARCHITECT STAMP2017MCG PROJ. MANAGER:MCG PROJ. SPECIALIST:MCG PROJECT #:THESE DRAWINGS AND SPECIFICATIONS ARECONFIDENTIAL AND SHALL REMAIN THE SOLEPROPERTY OF STARBUCKS CORPORATION,WHICH IS THE OWNER OF THE COPYRIGHT INTHIS WORK. THEY SHALL NOT BEREPRODUCED (IN WHOLE OR IN PART), SHAREDWITH THIRD PARTIES OR USED IN ANY MANNERON OTHER PROJECTS OR EXTENSIONS TO THISPROJECT WITHOUT THE PRIOR WRITTENCONSENT OF STARBUCKS CORPORATION.THESE DRAWINGS AND SPECIFICATIONS AREINTENDED TO EXPRESS DESIGN INTENT FOR APROTOTYPICAL STARBUCKS STORE (WHICH ISSUBJECT TO CHANGE AT ANYTIME) AND DONOT REFLECT ACTUAL SITE CONDITIONS.NEITHER PARTY SHALL HAVE ANY OBLIGATIONNOR LIABILITY TO THE OTHER (EXCEPT STATEDABOVE) UNTIL A WRITTEN AGREEMENT ISFULLY EXECUTED BY BOTH PARTIES.mcg architecture8/30/2017 5:43:46 PMJ:\2016 Projects\0-Starbucks\16514_SBX-6970_El Dorado & Fremont_Stockton_CA (NS-RELO)\02-Arch\3-CD\1-Revit Files\16514_SBX-6970_El Dorado & Fremont_Stockton.rvtI-110321295-04208/18/17ELDORADO &FREMONT510NELDORADOSTREETSTOCKTON, CA 95202SANJOAQUIN COUNTYCORE6970CH. LINM. DARMOKOFLOOR PLANC. LEEG. MONTALVO1651402' 4' 8'Scale: 1/4" = 1'-0"NScale:1/4" = 1'-0"11ST FLOOR - FLOOR PLANRevision ScheduleRev Date By Description