3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2000 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 2:39:12 PM
Creation date
3/26/2019 2:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000 - 2006
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page Z of 7 <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Equipment Used: DIAL GAUGE Equipment Resolution: 0 to 15" Hg Vacuum <br />Tank # 811 Tank # I Tank # Tank # <br />k <br />Is Tank Exempt From Testing?' ❑ Yes fR No ❑ Yes M No ❑ Yes ❑ No ❑ Yes ❑ No <br />Tank Capacity: <br />/O^ALLONS <br />OAMGALLONS <br />GALLONS GALLONS <br />Tank Material: <br />14 <br />t <br />Tank Manufacturer: <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />15 Minutes <br />15 Minutes <br />15 Minutes 15 Minutes <br />Test Start Time: <br />12: Q <br />A ; <br />Initial Reading (Rj): <br />"HG <br />I d "HG <br />"HG "HG <br />Test End Time: <br />! 0) <br />2--'3-6 <br />Final Reading (RF): <br />-HG <br />10 "HG <br />"HG "HG <br />Test Duration: <br />1 Hour <br />1 Hour <br />1 Hour 1 Hour <br />Change in Reading (RF -R,): <br />6) "HG <br />C) "HG <br />"HG "HG <br />Pass/Fail Threshold or Criteria: <br />Zero <br />Zero <br />Zero Zero <br />Test Result:_ <br />Pass p bail <br />Pass ❑ Faf <br />Kp %'assr: Cia�l ❑ Piss'3 Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />BP/Arco #02186 <br />3212 N California <br />Stockton, CA. 95204 <br />N04731 — SB 989 Testing <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)) <br />