My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0079470
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SECTION
>
3413
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0079470
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2019 9:00:55 AM
Creation date
3/27/2019 8:27:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0079470
PE
2602
STREET_NUMBER
3413
Direction
E
STREET_NAME
SECTION
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
17309032
ENTERED_DATE
8/6/2018 12:00:00 AM
SITE_LOCATION
3413 E SECTION AVE
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S = Sufficient <br /> I = Insufficient <br /> S I 6.0 PERCOLATION TEST INFORMATION SECTION <br /> ® ❑ 6.1 Site map showingtI�e location with concise and accurate dimensions of the percolation test holes on the parcel. <br /> A��Pc•�:t ix 4, <br /> [ ]C ❑ 6.2 The minimum number of shallow and deep percolation tests was performed for each parcel. Plj q <br /> ❑ 6.3 Description of the date,time and protocol used to prepare the test hole, including depth and dimensions of hole, <br /> preparation of hole, and depth of water used to presoak(minimum 12 inches). f>g tj <br /> CR ❑ 6.4 Description of the date, time and condition of the test hole after the 24-hour soak period (hole still intact, hole dry, <br /> depth to water remaining in hole, etc.) ®� <br /> ❑ 6.5 The test conformed to SJC Policy EHD 02-02 (correct depth, diameter, 2"gravel, 6"water refill, correct readings <br /> recorded). F'5 ifs <br /> 6.6 Complete Percolation Test Form (including readings)was provided with REHS verification signature. The rate <br /> was correctly calculated using the last reading. <br /> ❑ 6.7 Discussion of any potential problems predicted and/or the need for an engineered or alternative septic system. <br /> ❑ 6.8 Discussion of percolation rates in relation to the type, size and location of future leach fields needed at the site. <br /> 7.0 CONCLUSION SECTION <br /> ❑ 7.1 The report was signed and stamped by the appropriately registered individual <br /> Reviewed By: AVA-J l� / Reviewed Date: <br />
The URL can be used to link to this page
Your browser does not support the video tag.