My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
3310
>
2800 - Aboveground Petroleum Storage Program
>
PR0528487
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2019 4:31:40 PM
Creation date
3/27/2019 8:43:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0528487
PE
2832
FACILITY_ID
FA0009490
FACILITY_NAME
KENTS OIL SVC INC
STREET_NUMBER
3310
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
14339005
CURRENT_STATUS
01
SITE_LOCATION
3310 E MINER AVE
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLAN FIELD <br /> (3) Is there drainage of uncontaminated rainwater from diked areas into ❑Yes El No ❑NA [—]Yes ❑No ENA <br /> a storm drain or open watercourse? <br /> If YES a Bypass valve normally sealed closed ❑Yes ❑No ❑NA ®Yes ❑No El NA <br /> • Retained rainwater is inspected to ensure that its presence will [—]Yes ❑No ❑NA El Yes El No ❑NA <br /> not cause a discharge as described in§112.1(b) <br /> Bypass valve opened and resealed under responsible ❑Yes [I No ❑NA ❑Yes ❑No ❑NA <br /> supervision <br /> • Adequate records of drainage are kept; for example, records ❑Yes ❑No ❑NA ❑Yes ®No EINA <br /> required under permits issued in accordance with 40 CFR <br /> §§122.410)(2)and(m)(3) <br /> (4) For completely buried metallic tanks installed on or after January 10, <br /> 1974(if not exempt from SPCC regulation because subject to all of <br /> the technical requirements of 40 CFR part 280 or 281): <br /> • Provide corrosion protection with coatings or cathodic ❑Yes ❑No ❑NA ❑Yes ❑No 0 NA <br /> protection compatible with local soil conditions <br /> • Regular leak testing conducted ❑Yes ❑No []NA ❑Yes [:]No ❑NA <br /> (5) The buried section of partially buried or bunkered metallic tanks ❑Yes El No [INA NA ❑Yes ❑No ❑NA <br /> protected from corrosion with coatings or cathodic protection <br /> compatible with local soil conditions <br /> (6) Test or inspect each aboveground container for integrity on a ❑Yes ❑No DNA ❑Yes ❑No [INA <br /> regular schedule and whenever you make material repairs. <br /> Techniques include, but are not limited to: visual inspection, <br /> hydrostatic testing, radiographic testing, ultrasonic testing, <br /> acoustic.emissions testing, or other system of non-destructive <br /> testing <br /> Appropriate qualifications for personnel performing tests and []Yes [:]No DNA ❑Yes ❑No ❑NA <br /> inspections are identified in the Plan and have been assessed <br /> in accordance with industry standards <br /> • The frequency and type of testing and inspections are []Yes ❑No ❑NA []Yes ❑No ❑NA <br /> documented, are in accordance with industry standards and <br /> take into account the container size, configuration and design <br /> • Comparison records of aboveground container integrity testing ❑Yes —]No []NA ❑Yes ❑No ❑NA <br /> are maintained <br /> • Container supports and foundations regularly inspected []Yes ❑No []NA ❑Yes ❑No ❑NA <br /> • Outside of containers frequently inspected for signs of ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> deterioration, discharges, or accumulation of oil inside diked <br /> areas <br /> • Records of all inspections and tests maintainedi5 []Yes ❑No ❑NA '. Yes ❑No ❑NA <br /> Integrity Testing Standard identified in the Plan: <br /> STI SP001 ED. 4 FOR SHOP-BUILT TANKS (WHICH DOES NOT APPLY TO TANKS HEATED >200 DEGREES F); <br /> API 653 FOR FIELD ERECTED TANKS; API 650 IS ALSO IDENTIFIED, A CONSTRUCTION (NOT TESTING) STD. <br /> 112.12 Conduct formal visual inspection on a regular schedule for bulk ❑Yes ©No ❑NA ❑Yes [—]No ❑NA <br /> (c)(6)(11) storage containers that meet all of the following conditions: <br /> (Applies 10 •Subject to 21 CFR part 110; • Have no external insulation;and <br /> AFVO Facilities .Elevated; •Shop-fabricated. <br /> only) • Constructed of austenitic stainless <br /> steel; <br /> In addition, you must frequently inspect the outside of the container ❑Yes [:]No ❑NA ❑Yes [:]No ❑NA <br /> for signs of deterioration, discharges, or accumulation of oil inside <br /> diked areas. <br /> You must determine and document in the Plan the appropriate ❑Yes [:]No ❑NA ❑Yes [:]No ❑NA <br /> qualifications for personnel performing tests and inspections.18 <br /> 15 Records of inspections and tests kept under usual and customary business practices will suffice <br /> Onshore Facilities(Excluding Oil Production) Page 12 of 14 June 2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.