My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2022 4:54:02 PM
Creation date
3/27/2019 1:36:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE r-4Nx <br />RESPONSE PLAN - PAGE 2 <br />This information is required only for motor vehicle fuel UST systems cars>ructed per the Af the Leal< <br />ltemate Construction Requirements of23 CCR §2633, and only t <br />Interception and Detection System (LIDS) does not meet the volumetric requirements of 23 CCR §2631(d)(1) through (5) (i e, when account ng for rainfall and <br />backfill material, the secondary containment volume is less than 100% of primary tank volume for a single UST; or in the case of multiple LISTS in shared secondary <br />containment, 150% of the largest primary tank volume or 10`/0 of aggregate primary tank volume, whichever is greater) <br />AT IACH AN ADDI I ZONAL PAGE I'o THIS PLAN CON I AINING I HE F OI L O W NG INFORMATION'. <br />)> Thevolumeofthe LIDS in relation to the volume of the primary container; <br />➢ the amount of time the LIDS shall provide containment related to the time between detection of an unauthorized release and cleanup of the leaked substance; <br />➢ The depth from the bottom of the IfDS to the highest anticipated level of groundwater, <br />➢ the nature of the unsaturated soils under the LIDS and their ability to absorb contaminants or to allow movement of contaminoanent and are located in the <br />➢ the methods and scheduling for removal of all hazardous substances which may have been discharged from primary — <br />unsaturatcdsods between the primary cvtrtainment and groundwater mcludtn the LJDS sump — . — <br />-- . —�-- <br />'`- ' K gJ-1: AND REC(IRD <br />We will report/mcord any over611, spill, or unauthorized release from a UST system as indicated in this plan <br />Recordable Releases: Any unauthorized release from primary containment which the USI operator a able es clean up within eight (8) hirers after the release does <br />detected or should reasonably have been detected and which does not escape from secondary containment, does not increase the hazard of fire or explosion and does <br />not cause any deterioration of secondary containment, mast be recorded in the facility's monitoring records Monitoring records must include: <br />➢ The UST operator's name and telephone number; <br />➢ A list of the types, quantities, and concentrations of hazardous substances released; <br />➢ A description of the actions taken to control and clean up the release; <br />➢ The method and location of disposal of the released hazardous substances, and whether a hazardous waste manifest was or will be used; <br />➢ A description of actions taken to repair the UST and to prevent future releases; <br />➢ A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment <br />rimary <br />ment if no secondary <br />ary containment (or <br />ontain <br />Reportable Releases: acrd of fire lll, spill, or explosion, r aures anyorized uthldeteriorartion ofse ondarych escapes from swntatnment is a reportable erclease cReportable releases are also reco dablent <br />exists), increases the hoz <br />nistedrig the US I <br />Within i <br />aalmdetected, been <br />detected, will <br />the <br />local agency rcdl <br />release, nvestigaa the release, and take immediate measureto sop he release If necesay, or if required by the local agency, remaining stored product/Waste it <br />be removed <br />from the UST to prevent further releases or facilitate corrective action If an emergency exists we will notify the State Office of Emergency Services <br />Within five (S) working days of a reportable release, we will submit to the local agency a full written report containing all of the following information to the extent <br />that the information is known at the time of filing the report: <br />➢ The UST owner's or operator's name and telephone number; <br />➢ A list of the types, quantities, and concentrations of hazardous materials released; <br />➢ The approximate date of the release; <br />➢ the date on which the release was discovered; <br />➢ the date on which the release was stopped; <br />➢ A description of actions taken to control and/or stop the release; <br />stigations which were ur.derteken and will be conducted to determine the nature and extent o <br />3> A description of corrective and remedial actions, including im-e <br />soil. groundwater or surface water contamination due to the refcase; <br />9 The methods) of cleanup implemented to date, proposed cleanup actions, and a schedule for implementing the proposed actions; <br />➢ the method(s) and location(s) on(s) of disposal of released hazardous materials and any contaminated soils, groundwater, or surface water <br />ous wastes <br />➢ Copies of any hazardous methods tomaifestsfor repaused ir replacement of UST sytransport of r associated <br />em primary/secondary contalinment systems; <br />)>A description ofproposed <br />➢ A description of additional actions taken to prevent future releases <br />We will follow the reporting procedures described above if any of the following conditions occur' <br />➢ A recordable unauthorized release can not be cleaned up or is still under investigation within eight (8) hours of detection: <br />➢ Released hazardous substances are discovered at the US'T site or in the surrounding area; <br />3> Unusual water in the tank, neo conditiare ons <br />equipment is acluding erratic found o be defectivevand is immediately repaired orior of product dispensing replaced, Placed, dand No leak has occurred e unexplained presence o <br />➢ Monitoring results Eton UST system monitoring equipmendmcthods indicate that a release may have occurred, unless the monitoring equipment is found to be <br />defective and is immediately repaired, recalibrated or replaced, and additional monitoring does not confirm the initial results <br />e location, if <br />Record Retention: Monitoring records and written reports of unauthorized releases most maintained <br />emsts) must be mainttain d for at least 3 years froe (0, off-site at a readily m the date of shipent approved <br />by the local agency) for at least 3 years Hazardous waste shippmg/disposal records ("g-, <br />I .0. `R/OPERA`I`OR SIan <br />(UNATARE --_ -- - <br />CERTIFICATION: RI cge�rrtify that the info, mation provided herein is true and accuratetothe bestof my knowledge. <br />-'R70 <br />F�Aj C C� ! A <br />OVJNER/OP <br />(print) <br />KEVIN VO <br />pgmg Use Only) This plan <br />Local Agency Signature: <br />Arco # 02186, Belshire Environmental Services <br />771OWNER/OPERATORTITIE <br />DEALER <br />and: Approved p Approved With Conditions 0 Disapproved <br />� / <br />__'1_1 Date: U 1 U <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.