Laserfiche WebLink
UNDERGROUND STORAGE TANK <br />MONITORING PLAN - PAGE 2 <br />"IT ' VI. DISPENSER MONITORING <br />MONITORING OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) Mso. <br />® 1. CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER: Veeder Root M"- MODEL #: TLS 350 Msz. <br />LEAK SENSOR MANUFACTURER: — Veeder Root W'- MODEL #(S): 794380-323 M54. <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ® a. YES ❑ b. NO Mss. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES ❑ b. NO M56. <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a. YES ❑ b. NO M57. <br />❑ 2. MECHANICAL ASSEMBLY (e.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: M58 MODEL #(S): M59. <br />❑ 3. VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY (Requires agency approval) Mho. <br />❑ 4. NO DISPENSERS <br />M61. <br />❑ 99. OTHER (Specify) <br />VII. ENHANCED LEAK DETECTION <br />❑ 1. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN. PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. TRAINING <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) Mso. <br />1. ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required)* <br />3. ® THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of MM/DD/YY) <br />4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />99. El OTHER (Specify): Mal. <br />Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br />By 1/1/2005, this facility will have a "Designated UST Operator" who has passed the operator exam administered by the International Code Council (ICC). By July 1, <br />2005, and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems. This training <br />will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the leak detection equipment. <br />➢ The facility employee's role with regard to spills and overfills. <br />➢ Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after July 1, 2005, the initial training will be conducted within 30 days of the date of hire. <br />IX. COMMENTS/ADDITIONAL INFORMATION <br />Please use this section to include any additional UST system monitoring-related information (e.g., additional information required by your local agency): Mas. <br />*Monitoring systems manual maintained by contracted, licensed pump and tank technicians. <br />Best Management Practices are maintained in the H.S.S.E. Retail Facility Programs Manual (Green Binder). <br />*Tank Overfill Protection Type: High Level Alarm and Ball Float, alarm visual and audible at tank fill point(s) and <br />operates alarm trigger at 90%. <br />X. PERSONNEL RESPONSIBILITIES <br />THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEFORMING MONITORING. BP WEST COAST PRODUCTS <br />LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT. <br />M. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />OWNER/OPE OR SIG NATU E REPRESENTING <br />DATE: J/ M91. <br />❑ Owner M90 <br />I I <br />® Operator <br />l <br />OWNER/OPE TORN (print): M92. <br />OWNER/OPERATOR TITLE: <br />KEVIN VO <br />DEALER <br />(Agency Use Only) This plan has been reviewed and: ❑ Approved *Approved With Conditions❑ Disapproved <br />Local Agency Signature: D te: <br />I �� Y <br />Comments/Special Conditions: Y L I Q ✓ ' "' <br />qt AVKA" <br />Arco # 02186, Belshire Environmental Services Page 2 of 5 <br />