My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2022 4:54:02 PM
Creation date
3/27/2019 1:36:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Arco 9 02186, Belshire Environmental Services <br />Page 4 of 5 <br />UNDERGROUND STORAGE TANK <br />RESPONSE PLAN - PAGE 2 <br />VI::'LEAK IINTERCET�ON ANDETGT'Y(' SYSTEM :...:.: ..... ... <br />This information is required only for motor vehicle fuel UST systems constructed per the Alternate Construction Requirements of 23 CCR §2633, and only if the Leak <br />Interception and Detection System (LIDS) does not meet the volumetric requirements of 23 CCR §2631(d)(1) through (5) (i.e., when accounting for rainfall and <br />backfill material, the secondary containment volume is less than 100% of primary tank volume for a single UST; or in the case of multiple USTs in shared secondary <br />containment, 150% of the largest primary tank volume or 10% of aggregate primary tank volume, whichever is greater) <br />AI'IACH AN ADDIIIONAL PAGE TO THIS PLAN CONIAINING IHE FOLLOWING INFORMATION: <br />➢ The volume of the LIDS in relation to the volume of the primary container; <br />➢ I'he amount of time the LIDS shall provide containment related to the time between detection of an unauthorized release and cleanup of the leaked substance; <br />➢ the depth from the bottom of the I IDS to the highest anticipated level of groundwater; <br />➢ the nature of the unsaturated soils under the LIDS and their ability to absorb contaminants or to allow movement of'contaminants; <br />➢ The methods and scheduling for removal of all hazardous substances which may have been discharged from primary containment and are located in the <br />unsaturated soils between the primary containment and EZRunclwater, includin the LIDS sum . <br />We will report/record any overfill, spill, or unauthorized release from a UST system as indicated in this plan <br />Recordable Releases: Any unauthorized release from primary containment which the USI operator is able to clean up within eight (8) hours after the release was <br />detected or should reasonably have been detected„ and which does not escape from secondary containment, does not increase the hazard of fire or explosion. and does <br />not cause any deterioration of secondary containment, must be recorded in the facility's monitoring records Monitoring records must include: <br />➢ The UST operator's name and telephone number; <br />A list of the types, quantities, and concentrations of hazardous substances released; <br />➢ A description of the actions taken to control and clean up the release; <br />➢ The method and location of disposal of the released hazardous substances, and whether a hazardous waste manifest was or will be used; <br />A description of actions taken to repair the UST and to prevent future releases; <br />A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment <br />Reportable Releases: Any overfill, spill, or unauthorized release which escapes from secondary containment (or primary containment if no secondary containment <br />deterioration of secondary containment, is a reportable release Reportable releases are also recordable <br />exists), increases the hazard of fire or explosion, or causes any <br />Within 24 hours after a reportable release has been. detected, or should have been detected, we wilt notify the local agency administering the USI program of the <br />by local agency, remaining stored product/waste will <br />release, investigate the release, and take immediate measures to stop the release If necessary, or if required the <br />be removed from the UST to prevent further releases or facilitate corrective action If an emergency exists we will notify the State Office of Emergency Services <br />Within five (5) working days of a reportable release, we will submit to the local agency a full written report containing all of the following information to the extent <br />that the information is known at the time of filing the report: <br />➢ T he UST owner's or operator's name and telephone number; <br />➢ A list of the types, quantities, and concentrations of hazardous materials released; <br />➢ The approximate date of the release; <br />➢ The date on which the release was discovered; <br />➢ I'he date on which the release was stopped; <br />➢ A description of actions taken to control and/or stop the release; <br />➢ A description of corrective and remedial actions, including investigations which were undertaken and will be conducted to determine the nature and extent of <br />soil, ground water or surface water contamination due to the release; <br />➢ The method(s) of cleanup implemented to date, proposed cleanup actions; and a schedule for implementing the proposed actions; <br />➢ The method(s) and location(s) of disposal of released hazardous materials and any contaminated soils, groundwater, or surface water <br />➢ Copies of any hazardous waste manifests used for off-site transport of hazardous wastes associated with clean-up activity; <br />➢ A description of proposed methods for any repair or replacement of UST system primary/secondary containment systems; <br />➢ A description of additional actions taken to prevent future releases <br />We will follow the reporting procedures described above if any of the following conditions occur: <br />➢ A recordable unauthorized release can not be cleaned up or is still under investigation within eight (8) hours of detection; <br />➢ Released hazardous substances are discovered at the UST site or in the surrounding area; <br />➢ Unusual operating conditions are observed, including erratic behavior of product dispensing equipment, sudden loss of product, or the unexplained presence of <br />water in the tank, unless system equipment is found to be defective and is immediately repaired or replaced, and no leak has occurred; <br />may have occurred, unless the monitoring equipment is found to be <br />➢ Monitoring results from UST system monitoring equipment/methods indicate that a release <br />defective and is immediately repaired, recalibrated., or replaced, and additional monitoring does not confirm the initial results <br />Record Retention: Monitoring records and written reports of unauthorized releases must be maintained on-site (or off-site at a readily available location, if approved <br />by the local agency) for at least 3 years. Hazardous waste shipping/disposal records (e g., manifests) must be maintained for at least 3 years from the date of'shipment. <br />VIII Ow"WOPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />R70 <br />OWNER/OP O A <br />DATE <br />R72 <br />R7I- <br />OWNER/OPE TOR NAME (print) <br />OWNER/OPERATORTITLE <br />KEVIN VO <br />DEALER <br />(Agency Use Only) This plan has been reviewed and: ru .Approved ❑ Approved With Conditions ❑ Disapproved <br />// `` <br />Local Agency Signature: Date: <br />Arco 9 02186, Belshire Environmental Services <br />Page 4 of 5 <br />