Laserfiche WebLink
�ZSANAAQUIN Environmental Health Department <br /> " '. � COUNTY <br /> Linda Turkatte, RENS, Director <br /> IZ Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> ® � Robert , lon, REHS <br /> cw� Jeff CarruescoescoREHS, RDI <br /> Michael Kith, REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu, REHS <br /> 12/11/2018 <br /> Delta Pump Stockton Armature & Motor Works <br /> 646 S. California St. <br /> Stockton CA 95203 <br /> RE: Well Pump Inspection <br /> Well Location: 2135 WAUDMAN AVE STOCKTON Permit#: WP0039089 Inspection Date: 12/11/2018 <br /> The Environmental Health Department recently conducted a water well pump inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> ❑x Inadequate Concrete Platform around Wellhead. Pedestal is cracked. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑x Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air Vent not Sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑ Excessive Vegetation or debris around Wellhead. <br /> (SJC Ord. Code, Section 9-1115.4.—Dangerous/Nuisance) <br /> Corrective Action: Remove and maintain debris and vegetation away from well area. <br /> If you have any questions, contact: Aaron Gooderham, Environmental Health Assistant (209) 468-3442 <br /> Michael Kith, REHS <br /> Program Coordinator <br /> CC: Attn: Dean Morris, 2135 Waudman Ave. Stockton 95209 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />