Laserfiche WebLink
Q P Vvmm, OPW 1 = 2200 Series Thread -On Single Wall Grade Level Spill <br /> R E T A I L F U E L I N G Containers with Replaceable Bellows <br /> ACOMPANt <br /> Installation and Maintenance Instructions <br /> Please read these warnings and assembly instructions com- PRODUCT <br /> pletely and carefully before starting . Failure to do so may <br /> cause product failure, or result in environmental contami- FlexWorks Primary Pipe 10 years from date of manufacture <br /> nation due to liquid leakage into the soil , creating hazard - All Products and re- 1 year from date of installation <br /> ous spill conditions . placement parts in- (proof of purchase from certified <br /> IMPORTANT: The OPW 1 -2200 Spill Container is preassem - stalled in the State of contractors/technicians required ) <br /> bled for your convenience and ease of installation . Check to California OPW warrants ongoing compliance <br /> make sure the unit is intact and undamaged and all parts Certified to California with the standards and specifica- <br /> have been supplied . Never substitute parts for those sup- CP-201 and/or CP-206 tions for the duration of the warran- <br /> plied . Doing so may cause product failure . Standards* ty period required by the State of <br /> WARNING - DANGER: Using electrically operated equip- California; this limited warranty is <br /> ment near gasoline or gasoline vapors may result in a fire or under the condition the equipment <br /> explosion, causing personal injury and property damage. Be was installed and maintained by <br /> sure that the working area is free from such hazards, and trained and certified contractors/ <br /> technicians unless noted in Installa- <br /> always use proper precautions . tion Manual . <br /> NOTE: Keep the riser pipe capped at all times when prod- All other Products and 1 year from date of manufacture** <br /> uct is in the storage tank, so the vapors cannot escape into replacement parts <br /> the environment. <br /> Notice: OPW products must be used in compliance with * Products certified to California CP-201 and/or CP-206 Stand - <br /> applicable federal, state, and local laws and regulations. ards have been factory tested and met all applicable perform <br /> Product selection should be based on physical specifica- mance standards and specifications and will have an OPW <br /> tions and limitations and compatibility with the environ- registration card enclosed/attached to the product, <br /> ment and material to be handled . All illustrations and spec- OPW's exclusive obligation under this limited warranty is, at <br /> ifications in this literature are based on the latest produc- its option, to repair, replace or issue credit ( in an amount not <br /> tion information available at the time of publication . Prices, to exceed the list price for the product) for future orders for <br /> materials, and specification are subject to change at any any product that may prove defective within the applicable <br /> time, and models may be discontinued at any time, in either warranty period . (Parts repaired or replaced under warranty <br /> case, without notice or obligation , are subject to prorated warranty coverage for remainder of <br /> OPW STANDARD PRODUCT WARRANTY TAG the original warranty period) . Complete and proper warranty <br /> Notice: FlexWorks by OPW, Inc., VAPORSAVER'' and all other claim documentation and proof of purchase required . All <br /> OPW products must be used in compliance with all applicable warranty claims must be made in writing and delivered dur- <br /> federal, state, provincial and local laws, rules and regulations. ing the applicable warranty period to OPW at OPW 9393 <br /> Product selection is the sole responsibility of the customer Princeton-Glendale Road Hamilton, Ohio, USA 45011 , Atten - <br /> and/or its agents and must be based on physical specifica- tion : Customer Service Manager. No products may be rem <br /> tions and limitations, compatibility with the environment and turned to OPW without its prior written authority, <br /> material to be handled . All illustrations and specifications in This limited warranty shall not apply to any FlexWorks or VA- <br /> this literature are based on the latest production information PORSAVERTM product unless it is installed by an OPW attested <br /> available at the time of publication . Prices, materials and installer and all required site and warranty registration forms <br /> specifications are subject to change at any time, and models are completed and received by OPW within 60 days of instal - <br /> may be discontinued at any time, in either case, without no- lation . This limited warranty also shall not apply to any Flex- <br /> tice or obligation . Works, VAPORSAVER'' or other OPW product: unless all pip- <br /> ing connections are installed with a nationally-recognized or <br /> OPW warrants solely to its customer (the initial purchaser and state-approved leak detection device in each tank and dis- <br /> any subsequent purchasers within the warranty period) that penser sump (which are not for storage and from which all <br /> the following products sold by OPW will be free from defects discharge hydrocarbons must be removed, and the systems <br /> in materials and workmanship under normal use and condi- completely cleaned, within 24 hours); unless testable sumps <br /> tions for the periods indicated : utilize FlexWorks pipe and access fittings; unless a sump in- <br /> spection log or an EPA recommended/required checklist is <br /> maintained and the results are furnished to OPW upon re- <br /> quest; and unless OPW is notified within 24 hours of any <br /> known or suspected product failure and is provided with un- <br />