COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 10:51:10 AM
Creation date
3/29/2019 10:37:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection ❑x 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID 10181387 Date of Overfill Prevention Equipment Inspection <br /> 1/15/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Ryder Truck Rental <br /> Business Site Address City ZIP Code <br /> 3633 Duck Creek Dr. Stockton 95215 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Robert Henninger 1 (408) 942-8686 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 396575 5252265-UT 7/13/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> Veeder-Root-A25027 04/15/19 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑Manufacturer Guidelines(Specify): <br /> Used: <br /> ❑x Industry Code or Engineering Standard(Specify): RP-1200 <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID:(By tank number,stored product, etc.) T1: Diesel T2: Diesel T3: Motor Oil T4: Used Oil <br /> What is the tank inside diameter?(Inches) 96" 96" 96" 64" <br /> Is the fill piping secondarily contained? 0 Yes ❑No I]Yes ❑No [E Yes ❑No 0 Yes ❑No <br /> Is the vent piping secondarily contained? [E]Yes 0 No 2 Yes ❑No 9 Yes ❑No ER Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder-Root Veeder-Root Veeder-Root Veeder-Root <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> ❑Q AN Alarm ❑x AN Alarm ❑x AN Alarm ❑x AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes 0 No ❑Yes ❑x No ❑Yes ❑x No ❑Yes ❑x No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 80.5" 80.5" 80.5" 53.5" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90% 90% 90% 90% <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑Q Yes ❑X Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results E Pass ❑Fail I Z Pass ❑Fail I ❑x Pass ❑Fail I]Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all <br /> the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Visual <br /> UN-109 www.unidocs.org 111 -Rev.06/14/18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.