Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 o;Inspection; <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection Z 36 Month <br /> 1 . FACILITY INFORMATION <br /> CERS ID 10181387 Date of Overfill Prevention Equipment Inspection <br /> 1 / 15/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Ryder Truck Rental <br /> Business Site Address City ZIP Code <br /> 3633 Duck Creek Dr. Stockton 95215 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Robert Henninger 1 (408 ) 942-8686 <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 396575 5252265-UT 7/ 13/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> Veeder- Root - A25027 04/15/ 19 t <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTIO I OORkATidiu <br /> Inspection Method ❑ Manufacturer Guidelines (Specify): r <br /> Used : <br /> Q Industry Code or Engineering Standard (Specify): RP- 1200 <br /> F <br /> ❑ Engineered Method (Specify): fc. / r� 0N r , c i <br /> i �z � i fl <br /> Attach the inspection procedures and all documentation required to determine the results. #o Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 : Diesel T2 : Diesel T3 : Motor Oil T4 : Used Oil <br /> What is the tank inside diameter? (Inches) 96 96" 96" 64 " <br /> Is the fill piping secondarily contained? ❑x Yes ❑ No El Yes ❑ No n Yes ❑ No ❑x Yes ❑ No <br /> Is the vent piping secondarily contained ? ❑x Yes ❑x No ❑x Yes ❑ No 0 Yes ❑ No 0 Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder-Root Veeder-Root Veeder-Root Veeder-Root <br /> I <br /> What is the overfill prevention equipment response <br /> E] Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? <br /> (Check all that apply.) ElRestricts Flow E] Restricts Flow [IRestricts Flow ❑ Restricts Flow <br /> Q AN Alarm 0 AN Alarm x❑ AN Alarm ❑x AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes ❑x No ❑ Yes E No ❑ Yes 9 No ❑ Yes [ig No <br /> At what level in the tank is the overfill prevention set „ „ „ „ <br /> E <br /> to activate? (Inches from bottom of tank.) 80 . 5 80 . 5 80 . 5 53 . 5 <br />[ What is the percent capacity of the tank at which the <br /> E overfill prevention equipment activates? 90 % 90 % 90 % 90 % <br /> Is the overfill prevention in proper operating condition ❑x Yes9 Yes 9 Yes FRI Yes <br /> to respond when the substance reaches the <br /> appropriate level? El No (Specify in V.) El No (Specify in V.) El No (Specify in V.) El No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 9Pass El Fail 9Pass ❑ Fail ❑x Pass ❑ Fail Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23, <br /> Division 3, Chapter 16, Section 2637 .2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> C If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Usual <br /> i <br /> UN -109 www.unidocs.org 1 /1 - Rev. 06/14118 <br /> II <br />