Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
R 0 innai. <br /> • : <br /> Water Temperature Control Simulation feed forward and feedback <br /> Remote Controls MC-91-1 US (included) <br /> Deluxe controller: MC-100V-1 US (optional) 98° - 140° F <br /> Bathroom controller: BC-100V-1 US (optional) <br /> Wireless controller: MC-502RC-1 US-MS (optional) <br /> MCC-91-1 US (for commercial applications) 98° - 160° F <br /> Remote Control Cable Non-polarized two-core cable, minimum 22 AWG <br /> Safety Devices • Flame failure - Flame Rod . Remaining flame (OHS) <br /> • Boiling protection . Thermal fuse <br /> • Combustion fan rpm check . Automatic frost protection <br /> • Over current-glass fuse (3 amp) <br /> Clearances from Combustibles • Top of heater-6 inches . Back of heater-0 inches <br /> (suitable for closet, attic, and • Front of heater-6 inches e Bottom of heater- 12 inches <br /> crawl space installations) • Sides of heater-2 inches e From vent pipe-0 inches <br /> Clearances from Non-combustibles • Top of heater-2 inches e Back of heater-0 inches <br /> • Front of heater-6 inches a Bottom of heater- 12 inches <br /> • Sides of heater- 1/2 inch . From vent pipe -0 inches <br /> Min./ Max. Gas Supply Pressure Natural Gas: min 5" W.C. max 10.5' W.C. <br /> Propane Gas: min 8" W.C. max 13.5' W.C. <br /> Manifold Gas Pressure (inches W.C.) Natural Gas: high fire 2.7 W.C. low fire 0.52" W.C. <br /> Propane Gas: high fire 4.4" W.C. low fire 0.92" W.C. <br /> NOx Meets California and Texas NOx Emission Rules <br /> Warranty Heat exchanger: 12 years*for residential and 5 years'for <br /> commercial and hydronic applications; (10 years' if used with the <br /> Rinnai Hydronic Air Handler); all other parts 5 years"; labor 1 year; <br /> (* 3 years if used as a circulating water heater within a circulation <br /> loop, when the water heater is in series with a circulation system <br /> and all circulating water flows through the water heater) <br /> Rinnai is continually updating and improving products,therefore, specifications are subject to change without prior <br /> notice. Local, state, provincial and federal codes must be adhered to prior to installation. <br /> 14(355.6) 9.6(244.5) WEIGHT: 50 LBS (23 KG) <br /> in (mm) <br /> I � � <br /> OD <br /> —�. <br /> N II c"l'•, 3.6(91)— 1.1 (27} 2.8(70) 319(99 <br /> I T I 4.3(110} 3.5(89) <br /> The wall bracket is adjustable to allow <br /> • an additional 1.57 inches (40 mm). <br /> Rinnai Corporation• 103 International Drive•Peachtree City,GA 30269•Toll-Free: 1-800-621-9419•Fax:678-364-8643•www.rinnaims <br />