My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2022 3:50:41 PM
Creation date
4/2/2019 11:05:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-'NIFIED PROGRAM CONSOLIDATED F <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK FORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST clan re or removal,complete only this section and Sections I,U Ill,IV,,and LY below) 430 <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430e I DATE EXISTING UST DISCOVERED: 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3 <br /> Flag City Chevron <br /> BUSINESS SITE ADDRESS 103. CITY IN <br /> 6421 Capitol Ave I Lodi <br /> H. TANK DESCRIPTION <br /> TANK ID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> Xerxes [3 2.ONE IN STAND-ALONE COMPARTMENTED UNIT comport Complete one page For each <br /> moot in the unit <br /> DATE UST SYSTEM INSTALLED 435. TANK CAPACITY IN GALLONS 436• NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 12,000 1 <br /> III. TANK USE AND CONTENTS <br /> TANK USE ® la MOTOR VEHICLE FUELING ❑ 1b.MARINA FUELING ❑ lc.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(lecrdes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ❑ 1a.REGULAR UNLEADED ❑ ]c.MIDGRADE UNLEADED ® lb.PREMIUM UNLEADED 44 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM(Spwtfy): 410a. <br /> NON-PETROLEUM:0 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM ): 4406. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 444L <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445• <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445x. <br /> OVERFILL PREVENTION ❑ 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL.TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL.PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 99.OTHER 460 <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR 12636(ex3)] 458. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464x. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 46415 <br /> 13 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c. <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL ® 2.DOUBLE WAIL ❑ 90.NONE 4644 <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ to.RIGID PLASTIC ❑ 90.NONE [399.OTHER(Specify): 464 1 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL, N 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 44G64f. <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL, N 4.FIBERGLASS [310.RIGID PLASTIC [390.NONE [399.OTHER(Specify): 4640.4n <br /> B <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 4464 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464i <br /> RISER PRIMARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 4640j <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 44"k. <br /> . <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATE/BOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP aslac:" <br /> VII. UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469x. <br /> CONSTRUCTION MATERIAL ❑ L STEEL ® 4.FIBERGLASS ® 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469e <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448 <br /> UL APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accurate,and in fullcompliance with legal requirements. <br /> APPLICANT SIGNATURE DATE 470 <br /> APPLICANT NAME(Print) , 471• APPLICANT TITLE 472. <br /> UPCF UST-B Rev.(12/2007)-IA www.unidocs.org <br />