Laserfiche WebLink
D PROGRAM CONSOLIDATED <br /> � uUNDERGROUND STORAGE TANK D ECEN\fMONITORING PLAN- a e 1 of 2 l� <br /> 4 <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 09 90-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490.2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): HEALTH <br /> I. FACILITY INFORMATION MITIS <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as Facility Name or DBA) Flag City Chevron 3 <br /> BUSINESS SITE ADDRESS 6421 Capitol Ave 103 CITY 95242 104 4 <br /> Lodi <br /> H. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annually,whichever is more fiequent.Such work must be performed by qualified personnel.[23 CCR§2632,2634,2638,26411 <br /> MONITORING E UIPMENT IS SERVICED ® 1.ANNUALLY [199.OTHERS i 490-3a. <br /> Q ( P��)� 490-3b. <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634) 4904. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Check <br /> h heck.11 <br /> 10 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 ccat§2632,26341 <br /> SECONDARY CONTAINMENT IS: ® a DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: Veeder Root 490-7. MODEL#: TLS350+ 490-9. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 49"- MODEL#(s): 794380-304 490.10' <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 ccR§26431 490-11. <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16• <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-1T <br /> PROGRAMMED TESTS: ❑ a 0.1 h. ® b.0.2 h. ❑ c.OTHERS a90-1s. <br /> &P• g•P• (Specify): ago-19. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[z3 ccR§2646.1) 490-20. <br /> E] 49 <br /> 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 cm§2645) TESTING PERIOD: ❑ a 36 HOURS ❑ b.60 HOURS 490-21. <br /> 0.22. <br /> ® 5.TANK INTEGRITY TESTING PER 12.3 ccR§2643.1) 490-23. <br /> TEST FREQUENCY: ® a IEN <br /> ANNUALLY ❑ b.BNIALLY [Ic.OTHER(Specify): 49490-24 <br /> ❑ <br /> 99.OTHER(Specify): 490-26. <br /> 490-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) "heck�ll <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMPS)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [§��j SECONDARY CONTAINMENT IS: ® a DRY ❑ b.LIQUID FILLED El c.PRESSURIZED ❑ d.UNDER VACUUM 4911-29. <br /> PANEL MANUFACTURER:Veeder Root 490.30. MODEL#: TLS350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-32. MODEL#(S): 794380-208 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(Le.,TURBINE)SHUTDOWN. ® a YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO ago-35. <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 cc3l§2636) q,,rn <br /> MLLD MANUFACTURER(S): AL <br /> 490-37. MODEL#(S). l-fl r+z 490-38. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 ccR§26361 490-39• <br /> ELLD N ANUFACTURER(S): 4900- MODEL#(S): 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a MINIMUM MONTHLY 0.2 g p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO 490-43- <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a YES ❑ b.NO 49044. <br /> ® 4.PIPE INTEGRITY TESTING. 490-45. <br /> TEST FREQUENCY: ® a ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 4904.497 <br /> ............. <br /> ❑ 5.VISUAL PIPE MONITORING. 490-48. <br /> FREQUENCY: ® a DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED. 490.49. <br /> •Allowed for m itoring of unburied effwrgency Seneralm fuel pipin8 only per HSC§25281.5(6)(3) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(ax3)] 490-50. <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ❑ <br /> 99.OTHER(Specify) 49492. <br /> 490.53. <br /> UPCF UST-D(12/2007)-1/3 www.unidocs.org <br />