Laserfiche WebLink
RESNA Industries Inc <br /> Quality Assurance/Quality Control Plan <br /> Rcvlstd November 1992 <br /> tubes The bottom tube will be sealed with aluminum foil or teflon tape and plastic end <br /> caps, taped and labeled with the following information• <br /> ✓ date and time <br /> ' ✓ project ID <br /> ✓ sample ID <br /> ✓ name of sampler <br /> ' ✓ type of analysis to be performed <br /> This sample will be immediately placed into a cooler containing dry ice or frozen <br /> chemical ice. A "high-low" temperature recording thermometer will accompany sample <br /> shipments to ensure proper temperature maintenance The samples will be delivered to <br /> ' a state certified laboratory following under chain-of-custody protocol within 48 hours of <br /> sampling, whenever possible <br /> Soil in the uppermost brass tube will be described according to ASTM standard practice <br /> for description and identification of soils (ASTM D-2488-84) Stratigraphic, genetic and <br /> ' other data/interpretations will also be recorded Soil properties may also be determined <br /> from the middle brass tube and from the sampler shoe Alternatively the second sample <br /> ' tube may be used with the uppermost tube for preparation of duplicates. These field <br /> observations will be noted on a log prepared for each boring/well. <br /> ' <br /> During sampling, latex gloves will be worn to prevent cross-contamination with other <br /> samples. The disposable gloves will be discarded after collecting samples from each 18- <br /> inch sample drive. <br /> QAQCIM FW[. 10 <br />