Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> IJ NIT Y_ Time In: 9:30 am <br /> ry Time Out: 10:30 am <br /> SclForit' Greotness grows here. <br /> Food Program Service Request Inspection Report <br /> Name of Facility: PREMIUM SPIRITS Date: 06/20/2019 <br /> Address: 2850 N CALIFORNIA ST, STOCKTON 95204 <br /> Requestor: SIMRANVEER SINGH, PREMIUM SPIRITS Telephone: (414)551-0530 <br /> Program Element: 1602-FOOD CONSULTATION Request#: SR0080759 <br /> Inspection Type: 061 -CONSULTATION <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Walk in cooler light bulbs are lacking covers. provid today. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored, served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Pipe, draining the left side compartment of the 2 comp sink, is leaking. Repair in 3 days. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #45 Floors,Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS:Walk in cooler floor is sticky with soda spill. clean today. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Name on Food Safety Certificate: Expiration Date: <br /> Warewash Chlorine(Cl): ppm Heat: °F Water/Hot Water Ware Sink Temp: 120°F <br /> Quaternary Ammonia(QA): ppm Hand Sink Temp: 120°F <br /> FA0002081 SR0080759 SC061 06/20/2019 <br /> EHD 16-23 Rev.06/30/15 Page 1 of 2 Food Program Service Request Inspection Report <br />