My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
REMOVAL 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 3:52:02 PM
Creation date
4/10/2019 11:09:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1995
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(TPHg and TPHd) using EPA Method 8015; and for benzene, toluene, ethylbenzene, and total xylenes <br /> (BTEX) using EPA Method 8020. Petroleum hydrocarbons were not detected in the soil samples ✓ <br /> collected from the sidewalls of the tank cavity (Table 1). Ground Zero collected three groundwater <br /> samples from the tank cavity and submitted the samples to Argon for analysis of TPHg using EPA <br /> Method 8015, and BTEX using EPA Method 8020. One of the water samples was also analyzed for <br /> TPHd using EPA Method 8015. Gasoline and diesel hydrocarbons were detected in the water samples <br /> collected from the tank cavity (Table 2). Laboratory reports and chain of custody records are included <br /> in Attachment B. <br /> On April 3, 1995 Ground Zero collected an additional water sample at a depth of approximately 6 feet <br /> bgs from the tank cavity and submitted the sample to Argon for analysis of TPHg and TPHd using EPA <br /> Method 8015 and BTEX using EPA Method 8020. Lower concentrations of gasoline hydrocarbons and <br /> diesel hydrocarbons were detected in the water sample (Table 2). Laboratory reports and chain of <br /> custody records are included in Attachment B. <br /> On April 11, 1995 Ground Zero collected two additional water samples from the tank cavity and <br /> submitted the samples to Argon for analysis of TPHg and TPHd using EPA Method 8015, and BTEX <br /> using EPA Method 8020. One of the water samples was also analyzed for total lead using EPA Method <br /> 7420. Petroleum hydrocarbons and lead were not detected in the water samples (Table 2). Laboratory <br /> reports and chain of custody records are included in Attachment B. <br /> On the afternoon of April 11 and the morning of April 12, 1995 SSSE deepened the tank cavity in order <br /> to remove potentially impacted saturated soil from beneath the former USTs. Approximately 180 <br /> additional cubic yards of saturated soil were bermed and stockpiled onsite in order to dry, and profiled <br /> for disposal. <br /> On April 12, 1995, at the direction of SJCPHS-EHD, Ground Zero collected three soil samples from <br /> the bottom of the deepened tank cavity at the locations shown on Figure 2. The samples were collected <br /> at a depth of approximately 14.5 to 15 feet bgs. The soil samples were sent to Argon and analyzed for <br /> TPHg and BTEX using EPA Methods 8015 and 8020, respectively. In addition, one sample was <br /> analyzed for TPHd using EPA Method 8015. Petroleum hydrocarbons were not detected in the soil <br /> samples collected at the bottom of the UST excavation (Table 3). Laboratory reports and chain of <br /> custody records are included in Attachment B. <br /> DISPENSERS AND PRODUCT LINES <br /> On April 5, 1995 Ground Zero collected soil samples from beneath the former dispensers and product <br /> lines at the locations shown on Figure 2. Soil samples were sent to Argon and analyzed for TPHg and <br /> BTEX using EPA Methods 8015 and 8020, and total lead using EPA Method 7420. Selected samples <br /> were also analyzed for TPHd using EPA Method 8015 (Table 4). Gasoline hydrocarbons were detected <br /> in the soil sample (1,313) collected at a depth of approximately 5 feet bgs from the eastern end of the <br /> southern dispenser/product line excavation. Petroleum hydrocarbons were not detected in any other soil./ <br /> samples. Total lead was not detected in soil samples collected from below the product lines and the/ <br /> dispensers. <br /> 2 <br />