My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
INSTALL 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 3:37:18 PM
Creation date
4/10/2019 1:40:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST SYSTEM PRINTSET INFORMATION <br />TANK # <br />/ <br /># <br />L <br />1. <br />/ <br />Four complete sets of plans (To include s Pecification sheets and/or equipment brochures if not on file). <br />2. <br />/a 000 <br />Plans drawn to scale in non -erasable print. <br />/O 0 0 D <br />MANUFACTURER <br />>02 CS <br />3• <br />Plot plan to show location and number of tanks. <br />4. <br />or <br />Tank cross-sectional diagram included on prints submitted. <br />[Sections 2635 (3) and 2631 (p)] <br />MODEL <br />5. <br />Detail of tank, piping system, excavation and cover. <br />6• <br />PRODUCT <br />Tank(s) and piping approved by a nationally recognized inde pendent testing organization. [Title 23, Subchapter 16, <br />Article 3, Sec. 2631 (r) & 26357 <br />Striker plate dimensions and materials. <br />7• <br />Verification of product compatibility with the tank(s), piping, monitoring <br />v <br />(2) <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)] <br />k <br />8• <br />COMPATIBILITY WITH 1001. <br />METHANOL <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)] <br />9. <br />✓ <br />Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />[Section 2635 (b) (6) & (7)] <br />Non -clad <br />steel tank [Section 2635 (b)] <br />10. <br />Double walled tanks using pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)] <br />11. <br />✓ <br />NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/EHD from the testing company or owner of facility. [Health <br />Approved by a corrosion engineer or N.A.C.E. technician. <br />& Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)] <br />12. <br />TANK CO MPM tTTnu <br />TANK # <br /># / <br /># <br />L <br />#3 <br />#� # <br />CAPACITY <br />OO U <br />/a 000 <br />/O OOQ <br />/O 0 0 D <br />MANUFACTURER <br />>02 CS <br />CZS <br />t S� <br />COMPOSITION <br />or <br />Fiberglass <br />[Sections 2635 (3) and 2631 (p)] <br />MODEL <br />PRODUCT <br />(1) <br />Striker plate dimensions and materials. <br />CORROSION PROTECTION <br />v <br />(2) <br />U.L. LISTED <br />k <br />COMPATIBILITY WITH 1001. <br />METHANOL <br />✓/ <br />(3) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />D. <br />13. TANK(s) TO BE <br />INSTALLED <br />_ A. <br />Steel -clad <br />with <br />fiberglass reinforced plastic. <br />_ B. <br />i <br />Holiday <br />test <br />required irtmediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)] <br />C. <br />Fiberglass <br />[Sections 2635 (3) and 2631 (p)] <br />(1) <br />Striker plate dimensions and materials. <br />v <br />(2) <br />Striker plate under all accessible openings. <br />✓/ <br />(3) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />D. <br />Non -clad <br />steel tank [Section 2635 (b)] <br />_ <br />(1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) <br />Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) <br />Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.