Laserfiche WebLink
8 NPT thteaded Thread preparation <br /> connections Inspect threads on fiberglass adapters and threaded bushings. <br /> Do not use if threads are damaged. <br /> • Inspect threads on steel fittings for burrs. <br /> • Remove burrs from steel fittings by making up to mating steel threads.Unmake <br /> the steel fitting and reinspect. <br /> r———————j—————— Always dry fit fiberglass and steel threads without sealing compound.It should <br /> be possible to dry fit the threads as shown in the following table.If the proper <br /> In general,threaded connections i number of threads cannot be made up,select a new steel fitting. <br /> should be made up before adhesive- <br /> bonded joints to minimize the I Making the joint <br /> possibility of damage to bonded joints I Threads must be clean and dry before applying thread-sealing compound. <br /> caused by torquing the threaded <br /> connections.However,when installing I • Use a nonhardening,solvent-free Teflon based thread sealant such as Jomar <br /> molded threaded bushings(tapered I Seal"The Heavyweight"or Gasoila Soft Set pipe sealant. <br /> major nominal pipe size x threaded 0 Apply sealing compound to male and female threads. r <br /> minor nominal pipe size)make the' 0 Hand tighten the joint,then <br /> tapered bonded joint first and allow it I use a wrench to get full Threads to Dry Fit and to Seal <br /> to cure before making up the threaded I make-up.Standard pipe Nominal <br /> I joint.This order of joint make-up will wrenches can be used with Pipe Size_ _ __ __ Threads to Additional <br /> prevent damage to the bushing. I care on fiberglass adapters: (in-) (mm) Dry Fit Threads to Seal <br /> Do not overtighten. <br /> 1112 40 4-5 3 <br /> L—————————————J • The parts should make up 2 50 4-5 3 <br /> the number of threads 3 80 5-6 3 <br /> shown in the table above. 4 100 6-7 2 <br /> Otherwise,a proper seal 6 150 7-8 2 <br /> may not be effected when -- - <br /> tightened. <br /> Isolating flex connectors at the shear valve <br /> r————————- When flex connectors are directly buried at the dispenser,regulations frequently <br /> Never use a pipe I require that they be cathodically protected and provisions be made to avoid stray <br /> wrench directly on the I current electrolysis and corrosion.In such cases the flex connector must be electrically <br /> I pipe:wrench up only I <br /> isolated from the shear valve and from other metallic components in the system. <br /> on adapters. I Experience has shown that nylon isolation adapters do not perform well inasmuch as <br /> J the poor mechanical strength of the material results in creep or thread deformation with <br /> L———————— <br /> subsequent leakage. <br /> Ameron manufactures a 1 lh NPT female x 11h NPT male fiberglass-reinforced <br /> isolation adapter which may be mounted between the flex connector and the shear <br /> valve. Follow the same general installation procedures as with other NPT threaded <br /> fittings.After applying the sealing compound,hand tighten the adapter.Final make-up <br /> requires 1 th to 2 additional turns. <br /> Shear valve <br /> .�1'/z NPT female <br /> 2'A 11b)VTDualoy isolation <br /> male A--�_adapter <br /> Fig.8-1.The Ameron fiberglass-reinforced A' <br /> isolation adapter is mounted between the <br /> ilex connector and the shear valve. 2,/a 1 a <br /> �M, <br /> SS flex connector <br /> 1'/2 NPT 1112 NPT male <br /> female both ends <br /> (by others) <br /> TY <br /> .y <br /> 12 <br />