COMPLIANCE INFO 2009 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO 2009 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 11:57:34 AM
Creation date
4/10/2019 3:28:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2013
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,e <br /> Appendix VI <br /> + <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California - <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of <br /> Regulations qP = �' <br /> Cr y� <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for '• 0, <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility FLAG CITY CHEVRON <br /> Bldg.No.: <br /> Site r�jt,T <br /> Addrmw 6421 CAPITOL AVE. City: LODI, CA Zip: 95242 <br /> Facility Contact <br /> Parcnn KIU Contact Phone No.: (2 9)334-1873 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 7/28/2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to i dicate specific equipment inspected/serviced: <br /> Tank ID: 87 MAIN Tank Size: Tank ID: 87 SLAVE Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> ® Mechanical Line Leak Detector. Model: STP MLD ® Mechanical Line Leak Detector. Model: STP MLD <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ® Other(specify equipment type and model in Section E on Page 2). ® Other(specify equipment type and model in Section E on Page 2) <br /> Tank ID: DIE Tank Size: Tank ID: 91 Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ® Fill Sump Sensor(s). Model: 208 ® Fill Sump Sensor(s). Model: 208 <br /> ® Mechanical Line Leak Detector. Model: STP MLD D ® Mechanical Line Leak Detector. Model: STP MLD <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ® Other(specify equipment type and model in Section E on Page 2). ® Other(specify equipment type and model in Section E on Page 2), <br /> Dispenser ID: 1/2 FD�ispenser ID: 3/4 <br /> ® Dispenser Containment Sensor(s), Model: 208 enser Containment=andChain(s). <br /> 08 <br /> ® Shear Valve(s). ar Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). enser Containment <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> E] Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9/10 DispenserlD: 11/12 <br /> ® <br /> ® Dispenser Containment Sensor(s). Model: 208 Sensor(s).Containment Model: 208 <br /> ® Shear Valve(s). ®Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ZANE A NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 - <br /> Testing Company Address: 416 2 STREET GALT,CA 95632 Date of Testing/Servicing: 7/28/10 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> sic- P-14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.