My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO 2009 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 11:57:34 AM
Creation date
4/10/2019 3:28:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2013
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 07/28/10 <br /> Facility Address: AMENDED REPORT 6421 Capitol Ave. Lodi, CA 95242 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct the routine inspection and witness the annual monitoring system certification. <br /> Violations: 6, 9, 13. Repeat Violations: 2, 4, 7, 14, 21, 21, 23c, 23d. <br /> #2 Secondary containment testing was last performed on 7-10-06 and was completed on 12-7-09, five <br /> months past due. Secondary containment testing is required once every 36 months. Take all necessary <br /> precautions to ensure testing is performed in a timely manner. <br /> #4 Financial responsibility documents were last submitted to the EHD for 6-25-09 and then again for <br /> 7-26-10, one month past due. Current financial responsibility documents are required to be submitted <br /> annually. Take all necessary precautions to ensure submittal of the financial responsibility documents <br /> are performed in a timely manner. <br /> #6 A copy of the UST operating permit was not found on site. A copy of the UST operating permit and <br /> all attachments and conditions shall be retained at the facility. Immediately obtain a copy of the permit <br /> and retain it on site. <br /> #7 Alarm maintenance records for the following alarms were not found on site. <br /> L5 91 stp sump fuel alarm on 12-7-09, L6 87 master stp sump fuel alarm on 12-7-09, L8 diesel stp sump <br /> fuel alarm on 12-7-09, L9 91 fill fuel alarm on 12-11-09 & 12-7-09, L10 87 master fill fuel alarm on <br /> 12-12-09, L11 87 slave fill fuel alarm on 6-16-10 & 1-19-10, L13 dispenser 1/2 fuel alarm on 8-30-09, <br /> These records shall be kept on site for at least 3 years . Immediately locate and maintain the alarm <br /> maintenance records for the above listed alarms on site and submit copies to the EHD by 8-28-10. <br /> #9 UDC 9/10 is has a loose fuel filter and diesel fuel is leaking out into the UDC. The underground <br /> storage tank system shall be operated to prevent unauthorized releases. Correct immediately. Stop the <br /> leak and properly dispose of the released diesel fuel per Title 22 Hazardous Waste Regulations. <br /> #13 The 91 fill sump sensor failed to activate an audible and visual alarm when tested to ensure <br /> continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm when it detects a leak. The sensor was replaced and retested during the <br /> inspection. Obtain a permit from the EHD for this work within one business day. If a permit is not <br /> obtained within one business day, a "Failure to Obtain a Permit" penalty will apply. Part# 0794380-208. <br /> Serial# 727372. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD In for _ R ceived By: Title: <br /> EHD 23-02-003 Rev 06/01/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.