Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.s'gov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 5 of 5 <br /> OFFICIAL INSPECTION REPORT Date: 07/28/10 <br /> Facility Address: AMENDED REPORT 6421 Capitol Ave. Lodi, CA 95242 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> #23c The designated operator failed to document all the alarms on the designated operator monthly <br /> inspection reports. The missing alarms include- L11 87 slave fill sump fuel alarm on 6-16-10 and L13 <br /> dispenser 1/2 fuel alarm on 8-13-09. During the monthly inspection, the designated operator shall review <br /> the alarm history for the previous month, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. <br /> #23c The designated operator failed to check and note the correct test dates for the secondary <br /> containment testing on the Sept. 2009 through July 2010 designated operator monthly inspection <br /> reports. The date of 8-14-09 was listed on these reports for the secondary containment tests. Sept. 2009 <br /> through Nov.2009 should have listed 7-10-06. Dec. 2009 through July 2010 should have listed 12-7-09. <br /> During the monthly inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the <br /> required information on the reports. <br /> #23d The designated operator employee training for Kiumars Khajevandi was last performed on 3-16-09 <br /> according to the D.O. training log and is four months past due. Kiumars Khajevandi was working alone <br /> at the gas station. The designated operator shall train facility employees for which he or she is <br /> responsible in the proper operation and maintenance of the UST system once every 12 months. The <br /> training shall include, but is not limited to- <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and <br /> submit a copy of the training records to the EHD by 8-28-10. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by 8-28-10. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Insp r: � .,� Received By: Title: <br /> In��Y �1 �' G��� <br /> EHD 23-02-003 Rev 06/0 /10 \ CONTINUATION FORM <br />