My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O A Q U I N Environmental Health Department <br /> —COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLAG CITY CHEVRON 6421 CAPITOL AVE, LODI September 26, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 9/26/2017 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by 10/26/17 . This <br /> information was not received within 30 days resulting in a non-compliant status for this facility. An operator that <br /> receives an inspection report shall have 30 days to submit a written response that includes a statement <br /> documenting corrective actions taken or proposing corrective actions which will be taken. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> report. <br /> This is a repeat violation, Class II. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to print L5 91 STP sump alarms from the attached alarm history on the 6/1/18 <br /> designated operator monthly inspection report. During the monthly inspection,the designated operator shall review <br /> the alarm history for the previous month, check that each alarm was documented and responded to appropriately, <br /> and attach a copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> This is a repeat violation, Class Il. <br /> 313 HSC 25290.1,25290.2,25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> The diesel product meter in UDC 9/10 had a visible seepage, indicating a leak in the primary piping. All primary <br /> containment for the UST system must be tight. Immediately have a properly licensed,trained, and certified <br /> contractor repair or replace the failed component under permit and inspection of the EHD, if required. <br /> This is a repeat violation, Class ll. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 product slave line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. <br /> A"UST Retrofit Verification with Inspector Already Onsite"form has been completed and provided to the operator <br /> and contractor. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by October 26th, 2018. <br /> Document reviewed: Monitoring system certification test results from 2015, 2016, 2017, secondary containment <br /> FA0000485 PR0231706 SCO01 09/26/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.