My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T 416 2nd Street ® Drop Tube Integrity <br /> Afforda- 1 eSt Ga1t087FA (20 ® Static Torque & Rotation <br /> (209)744-0112(800)524-9087 FAX(209)744-0116 <br /> TEST DATE: 9/26/2018 TIME: <br /> TECHNICIAN NAME: <br /> SITE NAME: FLAG CITY CHEVRON AIR QUALITY AGENCY: S J V A P C D <br /> ZANE NIMMO <br /> Site Address:6421 CAPITOL AVENUE INSPECTOR NAME: <br /> !declare, under penalty ojperjury under the laws of the state of <br /> City:LODI,CA 95240 California that based on information and belief formed after <br /> reasonable inquiry, the statementsand information provided in ❑ Present ® Not Present <br /> Phone: the document are true,accurate,and complete. <br /> Contact: <br /> ❑ Straight ® Overfill Prevention Device <br /> TECH SIGNATURE: <br /> Confirmation#18-25912 Permit Equipment: <br /> Facili # N-714 ❑Incline Manometer ®Flow Meter Calibrated Dail <br /> DROP TUBE & OVERFILL PREVENTION DEVICE PRESSURE INTEGRITY TEST <br /> Drop Tube Drain Valve Pressure Test Drop Tube Overfill Prevention Device Test "Corrected" Overfill Device Leak Rate <br /> Flow Rate 80ml/min .17 Flow Rate 200 ml/min .42 <br /> R-Regular Time to Minus Equals <br /> reach 2" Drain Valve Final Time to reach 2" Overfill Leak Final Overfill Device Drain Valve Corrected Lk Rate <br /> P=Plus H2O at 80 Leak Rate Pressure H2O at 200 ml rate Pressure Leak Rate Leak Rate for Overfill Device <br /> S=Super ml/min 2"H20-30 see 2"H20-30 See <br /> Tank Grade ml/min In H2O (in sec) ml/min In H2O ml/min ml/min mUmin <br /> 87 AUX 149 0 2.06 PASS <br /> 91 153 0 2.07 PASS <br /> 87 MAIN 162 0 2.01 PASS <br /> STATIC TORQUE & ROTATION <br /> Vapor Adaptor: 1 2 3 4 Product Adaptor: 1 2 3 4 <br /> Brand: O P W Brand: O P W <br /> Model; AUX MAIN Model: AUX MAIN <br /> Product Grade: 87 91 87 Product Grade: 87 91 87 <br /> Torque#1: 85 45 95 Torque#1: 75 50 75 <br /> Torque#2: 1 85 1 45 1 95 1 Torque#2: 75 50 75 <br /> Torque#3: 85 45 95 Torque#3 75 50 75 <br /> Average: 85 45 95 Average: 75 50 75 <br /> 360 Rotation YES YES YES --- 360 Rotation: YES YES YES --- <br />