Time In: 9 30 am
<br /> Time Out: 10:30 am
<br /> p44��0. San Joaquin County
<br /> ko
<br /> `? Environmental Health Department
<br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232
<br /> Vic., w Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd
<br /> q�/l�dRa\
<br /> Food Program Service Request Inspection Report
<br /> Name of Facility: COMMISSARY AZTECA Date: 03/22/2019
<br /> Address: 620 S SACRAMENTO ST, LODI 95240
<br /> Requestor: ALEJANDRO OCHOA, COMMISSARY AZTECA Telephone: (209)663-5815
<br /> Program Element: 1601 -FOOD PLAN CHECK Request#: SR0080253
<br /> Inspection Type: 523-Plan Check/Report Review
<br /> VIOLATIONS AND CORRECTIVE ACTIONS
<br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7;
<br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health
<br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of
<br /> the food facility.
<br /> #21 Hot and Cold Potable Water Not Available
<br /> OBSERVATIONS:3 comp sink has temp at 115F. Provide 120F or above.
<br /> CALCODE DESCRIPTION:An adequate,protected,pressurized,potable supply of hot water and cold water shall be provided at all times.
<br /> (113953(c), 114099.2(b) 114101(a), 114189, 114192, 114192.1, 114195)
<br /> #35 Equipment/Utensils Approved and in Good Repair
<br /> OBSERVATIONS:Walk in cooler compressor is leaking. Repair.
<br /> CALCODE DESCRIPTION:All utensils and equipment shall be fully operative and in good repair. (114175).All utensils and equipment
<br /> shall be approved, installed properly,and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5,
<br /> 114132, 114133, 114137, 114139, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114177, 114180, 114182)
<br /> #38 Approved 1 Sufficient Ventilation and Lighting
<br /> OBSERVATIONS:Light is inadequate in the walk in cooler and the meat prep area. Provide adequate light.
<br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by
<br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation
<br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft,or a
<br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas
<br /> to facilitate cleaning and inspection. Light fixtures in areas where open food is stored,served,prepared, and where utensils are washed
<br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #41 Plumbing Maintained;Approved Back Flow Device
<br /> OBSERVATIONS:Pipe, draining the 3 comp sink, is lacking air gap. Provide air gap at least 1 inch off the floor sink.
<br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required
<br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br /> ordinances,shall be maintained so as to prevent any contamination, and shall be kept clean,fully operative,and in good repair. Any hose
<br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171,
<br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br /> OVERALL INSPECTION NOTES AND COMMENTS
<br /> SR0080253 SC523 03/22/2019
<br /> EHD 16-23 Rev.06/30/15 Page 1 of 2 Food Program Service Request Inspection Report