Laserfiche WebLink
Tracy i-azda Waste Anti-Freeze Tank Assessment kz-009) <br /> Tracy Mazda <br /> Cylindrical Closed Top <br /> Material of Construction: LDPE <br /> Shell Height, in 50.000 <br /> Shell Diameter, in. 32.000 <br /> Volume of Tank, in3 40192.000 <br /> Volume of Tank, gallons 173.991 <br /> Working Volume, gal 157.000 <br /> S.G. of contents 1.100 <br /> Weight of Contents, lbs 1440.318 <br /> Tank Wall Thickness, mm 1.900 <br /> Tank Wall Thickness, in 0.075 <br /> Wt of Tank, lbs 16.481 <br /> Total Weight of Tank and Contents, lbs 1456.799 <br /> Zip Code 95037.000 <br /> Height of CG, in 22.500 <br /> Overturning Moment Arm, in 22.500 <br /> Resisting Moment Arm, in 16.000 <br /> Ss 1.500 <br /> SI 0.900 <br /> Soil Class D <br /> Fa 1.000 <br /> Fv 1.500 <br /> Sms 1.500 <br /> Sml 1.350 <br /> Sds 1.000 <br /> Shc 0.900 <br /> To 0.180 <br /> Ts 0.900 <br /> E, LDPE, psi 29000.000 <br /> I, in4 962.076 <br /> k, Ibf/in 7348.204 <br /> T, sec 1.707 <br /> Sa 0.527 <br /> Importance Factor 1.000 <br /> Seismic Shear Force, Ibf 768.087 <br /> Overturning Moment, inlbf 17281.962 <br /> Resisting Moment, inlbf 23308.777 <br /> Resisting Moment > O\,erturning Moment <br /> No Tension on Anchors <br /> Number of Anchors for Shear 1.000 <br /> Shear Strength of Anchor. Lbs 7200.000 <br /> Factor of Safety for Shear 9.374 <br /> Seismic/Anchoring findings: The tank as designed and operated, and the <br /> containment area in which it is located are adequately anchored and are <br /> seismically sound. Initials.- <br /> Strandberg <br /> nitials:Strandberg As-uciates 1(866)388-0404 (650) 329-8918 rwatergLly(a,rwaterjzLly.�:k_)ni 10 <br />