My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
1181
>
2200 - Hazardous Waste Program
>
PR0505942
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2024 11:46:54 AM
Creation date
4/12/2019 10:34:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0505942
PE
2249
FACILITY_ID
FA0007096
FACILITY_NAME
PG&E: McDonald Island Compressor Station
STREET_NUMBER
1181
Direction
N
STREET_NAME
ZUCKERMAN
STREET_TYPE
Rd
City
Stockton
Zip
95206
APN
129-310-12
CURRENT_STATUS
01
SITE_LOCATION
1181 N Zuckerman Rd
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2249_PR0505942_1181 N ZUCKERMAN_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
569
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.slgov.orq/ehd <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PG&E: McDonald Island Compressor Station 1181 N Zuckerman Rd, Stockton April 10, 2019 <br /> Universal Waste <br /> 713 HSC 25201.16(g) Failed to store used aerosol cans in an accumulation container ❑V ❑R ❑COS <br /> 714 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing ❑V ❑R ❑COS <br /> 715 HSC 25201.160) Failed to submit or amend notification for aerosol can processing ❑V ❑R ❑COS <br /> 716 CCR 66273.40(a)(3)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification ❑V ❑R ❑COS <br /> 717 CCR 66273.32(d) Failure of a UW handler to submit a complete annual report to DTSC ❑V ❑R ❑COS <br /> 718 CCR 66273.38 Failure of UW handler to transfer UW to the appropriate destination facility ❑V ❑R ❑COS <br /> 719 CCR 66273.31(a) UW handler caused improper disposal of UW ❑V ❑R ❑COS <br /> 720 CCR 66273.8(b) Conditionally exempt small quantity UW generator caused improper disposal of UW ❑V ❑R ❑COS <br /> Certified Appliance Recycler(CAR) <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) ❑V ❑R ❑COS <br /> 802 HSC 25211.2,25211.3 Failure of a CAR to provide docs that materials that require special handling have been removed ❑V ❑R ❑COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling ❑V ❑R ❑COS <br /> Other Violations <br /> 3110 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 3120 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 3130 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 3140 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3150 See below Unlisted AbandonmenUlllegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 301 CCR 66265.31 Facility not maintained to minimize the release of a hazardous waste. <br /> A crack was observed in the secondary containment for the K-1 and K-2 electric compressors. Oil was observed on <br /> the crack, on piping below the crack, and on the ground. During the inspection, absorbent was applied to the oil on <br /> the ground and the above crack and pipe were cleaned. Facilities shall be maintained and operated to minimize <br /> the possibility of a fire, explosion, or release of hazardous waste to air, soil, or surface water which could threaten <br /> human health or the environment. Immediately fix the leak,and manage according to Title 22 hazardous waste <br /> regulations. Submit a statement when the crack is repaired and how the waste was managed. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by May 10, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> Waste Streams: pipeline liquids containing benzene, used oil, oily debris, aerosol cans <br /> FA0007096 PR0505942 SC001 04/10/2019 <br /> EHD 22-03 Rev.09/22/16 Page 4 of 5 RCRA Large Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.