Laserfiche WebLink
MONIT- RING SYSTEM CERTIFIWTION <br /> Jse By All Jurisdictions Within the State of Califorr <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3 Title 23, alifornia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A General Information <br /> Facility Name: USA#03696(CHEVRON BRAND NAME) City: LODI CA Zip: 95242 <br /> Site Address: 2448 W KETTLEMAN LN Contact Phone No: 369-3124 <br /> @ LOWER SACRAMENTO RD Date of Testing/Service: 06/06/2005 <br /> Facility Contact Person: MGR-DAVE <br /> Make/Model of Monitoring System:TLS Work Order Number: 2236756 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-91 Tank ID: 2-87 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 355 Piping Sump/Trench Sensor(s). Model: 208 <br /> X Fill Sump Sensor(s). Model: 355 Fill Sump Sensor(s). Model: 355 <br /> Mechanical Line Leak Detector. Model: FX1V FX1V <br /> Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: TanklD: <br /> X In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: <br /> X Piping Sump/Trench Sensor(s). Model: 355 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 355 Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: FX1V Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ❑Dispenser Containment Sensor(s) Model: 7 Dispenser Containment Sensor(s) Model: <br /> X❑Shear Valve(s). X Shear Valve(s) <br /> ❑X Dispenser Containment Float(s)and Chain(s). X Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 7/8 <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> X❑ Shear Valve(s). 719Shear Valve(s). <br /> X Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> ' If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): ❑System set-up XD Alarm history report <br /> Technician Name(print): JOEY MESA Signature: <br /> Certification No.: 006-05-1532 License. No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N. MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 06/06/2005 <br /> Page 1 of 3 Based on CA form dated 03/01 <br /> Monitoring System Certification <br />