My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2001 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:19:58 AM
Creation date
4/26/2019 4:27:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2006
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P7hrsk1mil MONITORING SYSTEM CERTIFICATION <br /> or Use By All Jurisdictions Within the State of Cali;. j <br /> Authority Cited,Chapter 6.7, Health and Safety Code, Chapter 16, Division 3 Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner operator. a owner operator must submit a copy of this form tot the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ULTRAMAR#696 City. LODI CA Zip:95242 <br /> Site Address: 2448 W. KETTLEMAN LANE Contact Phone No:369-3124 <br /> LOWER SACRAMENTO RD. <br /> Facility Contact Person: MGR-BETH/ASST MGR-MIKE Date of Testing/Service: 09/12/2001 <br /> Make/Model of Monitoring System: GILBARCO EMC Work Order Number: 2218420 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/seryiced <br /> Tank ID SUP TanklD: PLS <br /> In-Tank Gauging Probe. Model: CAP PROBE 71 In-Tank Gauging Probe. Model: CAP PROBE <br /> Annular Space or Vault Sensor. Model: LIQUID SENSOR X Annular Space or Vault Sensor. Model: LIQUID SENSOR <br /> Piping Sump/Trench Sensor(s). Model: LIQUID FLOAT LIQUID FLOAT <br /> Piping SumplTrench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: LIQUID FLOAT LIQUID FLOAT <br /> X Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: FXIV X FXIV Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 61 SO X Tank OverfilUHigIn-Level Sensor. Model: 61 SO <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an an <br /> 71 In-Tank Gauging Probe. Model: CAP PROBE In-Tank Gauging Probe. Model: <br /> 79 Annular Space or Vault Sensor. Model L Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: LIQUID FLOAT Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: LIQUID FLOAT Fill Sump Sensor(s). Model: <br /> 71 Mechanical Line Leak Detector. Model: FXIV Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: 61SO Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser ID: 11b <br /> 71 Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s) Model: <br /> ® Shear Valve(s). ShearValve(s) <br /> ® Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> lspenser lspenser lu. <br /> 7 Dispenser Containment Sensor(s) Model Dispenser Containment Sensor(s). Model <br /> ® Shear Valve(s). 7 <br /> Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: <br /> 1-1 Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> © Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/seryiced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): System set-up report; ® Alarm history report <br /> PRINTED NAME:MICHAEL T LEVESQUE SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.