Laserfiche WebLink
San Joaquin County <br /> .� Environmental Health Department DIRECTOR <br /> ? —�—'' •� Donna Heran, RENS <br /> z 600 East Main Street <br /> Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> Robert McClellon. REHS <br /> Jeff Carruesco, REHS. RDI <br /> c .• - r Kasey Foley, REHS <br /> Website: www.sjgov.org/ehd Linda Turkatte, REHS <br /> 5, 2011 Phone: (209) 468-3420 <br /> Fax: (209) 464-0138 <br /> Eric Janzen <br /> Able Maintenance Inc <br /> 3224 Regional Parkway <br /> Santa Rosa, CA 95403 <br /> Re: USA #68153 2448 W. Kettleman Ln. Lodi, CA 95242 4-14-11 revised SR0061452 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the 4-14-11 revised application for a permit to include installation of OPW 10-series shear <br /> valves and bravo MO-400 offsets between dispenser and piping in the under dispenser <br /> containment. Original application includes install of two Gilbarco advantage (3+1) Dispensers <br /> and two Gilbarco Advantage (3+0) Dispensers, four Bravo conversion frames, de-manifold vent <br /> risers, install OPW 23-033 vent cap on new diesel vent riser, install husky 5885 <br /> pressure/vacuum vent cap on remaining gasoline vent risers, convert the existing Premium (91) <br /> UST to contain Diesel, and convert the existing Midgrade (89) UST to Premium (91) at the <br /> above noted address. The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Aris Cacapit at (209) 468-3453 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Leak detector test: Diesel and 91 leak detectors must be tested to confirm that the <br /> device can detect a leak of 3 gallons per hour at 10 psi. <br /> b. Line integrity test on the diesel, 91, and 87 product lines are required. <br /> c. Verify vapor recovery line and spill container are capped off. <br /> d. Verify Bravo conversion frame is installed per manufacturer's instructions. <br /> Please be aware that the facility cannot operate the UST system prior to the EHD <br /> inspection and approval. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br />