Laserfiche WebLink
JUN-24-2010 06:33 Service Station Systems 408 938 8888 P.05 <br /> Monitoring System Certification- Pak if 3 <br /> Site Address: 2448 W. Kettleman Ln. Date ofresting/Servicing: 5124110 <br /> D. Results of Testing/Servicing <br /> Software Version Installed- 122.00 <br /> Complete the foliowin checklist: <br /> 3 Yes ❑ No* Is the audible alarm operational? <br /> 2 Yes ❑ No's Is the visual alarm operational? <br /> z Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> Ig Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes to No* if alarms are relayed to a remote monitoring station, is all communications equipment(e.g. modem) <br /> IN N/A operational? <br /> Ig Yes C1 No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that ripply) Z Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? IX Yes ❑ No <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i,e. no <br /> lg N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s) and operating properly? if so, at what percent of tank capacity does the alarm tri er? 0 %, <br /> Ix Yes* ❑ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E, below_ <br /> ❑ Yes* [X No Was liquid found inside any secondary containment systems designed as dry systems? (Check all[hat apply) <br /> ❑ Product;❑ Water. if ves,describe causes in Section E. below. <br /> 18 Yes ❑ No* Was monitorings stem set-up reviewed to ensure proper settings? (Attach set-up reports, ifa; licable.) <br /> Yes [] No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below, describe how and when these deficiencies were or will he corrected. <br /> E. Comments; Replaced 89 Mechanical Leak Detector. <br /> Rewired 87 STP 208 sensor. <br /> Checked for ball floats -not located where required by inspector. <br /> Need to replace 87, 89 & 91 straight drop tubes with flappers. <br /> Technician Bryan Lundien installed drop tubes wlflapperss on 5/25110 <br />