My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986 - 2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
8115
>
2300 - Underground Storage Tank Program
>
PR0231563
>
COMPLIANCE INFO 1986 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2020 5:00:26 PM
Creation date
5/1/2019 1:13:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986 - 2004
RECORD_ID
PR0231563
PE
2361
FACILITY_ID
FA0000110
FACILITY_NAME
J & L MARKET
STREET_NUMBER
8115
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
FRENCH CAMP
Zip
95231
APN
19317003
CURRENT_STATUS
01
SITE_LOCATION
8115 S EL DORADO ST
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br /> Site Address: Date of Testing/Servicing: <br /> D. Results of TestinWSei-vicing <br /> Software Version Installed: <br /> Complete the following checklist: <br /> P"Yes ❑ No* Is the audible alarm operational? <br /> Q''Yes ❑ No* Is the visual alarm operational? <br /> es ❑ No* Were all sensors visually inspectrA functionally tested and confirmed operational? <br /> p'i'es ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br /> will not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> lr N/A operational? <br /> Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If ves: which sensors <br /> initiate positive shut-down? (Check all that apply) p'Sump/Trench Sensors-, ❑ Dispenser Containment <br /> Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Eff Y es; ❑No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> p"N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill int(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? ????% <br /> ❑ Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors_ probes, or other equipment <br /> replaced and list the manufacturer name and model for all replacement parts in Section E.below. <br /> Yes* ❑ No Was liquid found inside any secondary- containment systems designed as dry systems? (Check all that apply) <br /> O'Product; ❑Water. If ves, describe causes in Section E.below. <br /> Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings? <br /> es ❑ No* Is all monitoring ui ment operational per manufacturers cations? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: ;N��p����s 7- t <br /> +� 'c='�`cL /;'�=%�1� :,v �{-; �.�'R-fc;�v�:;.. ;-�'�S��L ��w-ZcC.�:_� •1�1���7�1� -I_ir�-C` <br /> �� <br />
The URL can be used to link to this page
Your browser does not support the video tag.