Laserfiche WebLink
r <br /> SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of'UST spill containment structures. The completed form and <br /> printouts from tests(if applicable),should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: J AND L MARKET Date of Testing: 05-23-13 <br /> Facility Address: 8125 ELDORADO STOCKTON CA <br /> Facility Contact: EUGENIA Phone: 209-982-0897 <br /> Date Local Agency Was Notified of Testing:04-10-13 <br /> Name of Local Agency Inspector(fpresent during testing): SAN JOAQUIN CO. STACY <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: AFFORDA TEST 4162 nd Street Galt,CA 95632 (209)744-0112 Fax:(209)744-0116 <br /> Technician Conducting Test: ❑ Lyle D.Nimmo ❑ Zane A.Nimmo ❑ David A. Winkler ® Felix G.Ramirez <br /> 5249115-UT 5263322-UT 5263373-UT 5273934-UT <br /> Credentials': ®ICC Service Tech. ® SWRCB Tank Tester <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br /> Test Equipment Used: TAPE!H2O Equipment Resolution: 1/16 <br /> Identify Spill Bucket (B'v Tank 1 87 2 91 3 DIE 4 <br /> Number, Stored Product, etc.) <br /> ® Direct Bury ®Direct Bury ® Direct Bury ❑Direct Bury <br /> Bucket Installation Type: ❑Contained in ❑Contained in <br /> ❑ Contained in Sump ❑Contained in Sump Sump Sum <br /> a Bucket Diameter: 11 11 I 1 <br /> Bucket Depth: 14 13 14 <br /> Wait time between applying <br /> vacuum/water and start of test: <br /> Test Start Time(TO: 1000 1000 1000 <br /> Initial Reading(R,): 13 12 13 <br /> Test End Time(TF): 1100 1100 1100 <br /> Final Reading(RF): 13 12 12 <br /> Test Duration(TF—Tj): 1 HOUR 1 HOUR 1 HOUR <br /> Change in Reading(RF-Ri): 0 0 0 <br /> Pass/Fail Threshold or <br /> Criteria: <br /> Test Result: E Pass ❑ Fail ® Pass ❑Fail ® Pass ❑ Fail El Pass ❑ Fail <br /> Comments— (include information on repairs made prior to testing, and recomniended follow-up for failed tests) <br /> OPW BUCKETS <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> 1 hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signature: Date:05-23-13 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However, local requirements <br /> may be more stringent. <br />