Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sj oq v.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J & L MARKET 8115 S EL DORADO ST FRENCH CAMP May 30 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -The Monitoring Plans incorrectly list Dan Mcllrath as the designated operator and 'second person having <br /> responsibility'. <br /> -The 91 Monitoring Plan lists the leak detector model as FXXIV. This is not a valid model number. Red Jacket makes a <br /> FXIV leak detector. <br /> -The 87 and diesel Monitoring Plans incorrectly list the leak detector models as 99LD2000. The tanks were observed <br /> having LD2000 models. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 106 CCR 2632(d)(2), 2634(e) Failed to have an approved UST response plan. <br /> The response plan is not current and/or not approved by the EHD. The Response Plan does not have an option <br /> marked in Section V. The response plan must be uploaded to the California Environmental Reporting System (CERS). <br /> Immediately log into CERS, upload the completed form, and submit for review by the EHD. Ensure a copy is available <br /> for inspection at any time. <br /> This is a Class II violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. The Monitoring Site Plan (map) does not include the <br /> locations of the piping and indicates sensors are located in UDCs-the site is using floats and chains. A site plan <br /> must be submitted identifying the locations where monitoring will be performed. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site <br /> Plan. <br /> This is a repeat violation, Class II. <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days. <br /> Secondary containment testing was performed on August 16, 2017 and a test report was submitted on September 25, <br /> 2017, one month late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a Class II violation. <br /> FA0000110 PR0231563 SCO01 05/30/2018 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 8 Underground Storage Tank Program OIR <br />