My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or,/q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD 4 LESS FUEL CENTER" 3408 MANTHEY RD, STOCKTON December 21, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents have not been submitted to the EHD. The most current Certification of Financial <br /> Responsibility and Letter from Chief Financial Officer are dated 11/21/14 Current financial responsibility documents <br /> are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br /> at http://cers.calepa.ca.gov/, and upload the required documents. In CERS under UST Facility Operating Permit <br /> Application, under Financial Responsibility Mechanism, only one mechanism should be checked. Remove 'yes' and <br /> replace this with 'no' for insurance. <br /> This is a minor violation. <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The response plan is not current and/or not approved by the EHD and has not been uploaded to California <br /> Environmental Reporting System (CERS). The response plan must be uploaded to the CERS. The response plan <br /> must be uploaded to the CERS. Immediately log into CERS, upload the completed form, and submit for review by <br /> the EHD. Ensure a copy is available for inspection at any time. <br /> The monitoring plan is not current and/or not approved by the EHD. The Leak Sensor Model number should be <br /> corrected to VR794390-460, and Periodic System testing should have"yes" for Secondary Containment Testing; the <br /> Personnel Responsibilities should name the correct person and provide the person's title, not 'contact'. Under Tank <br /> Monitoring is Performed Using the Following Methods, enter"yes" for continuous electronic tank monitoring. Also <br /> correct the Application Certification name and title. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit <br /> for review by the EHD. . Immediately log into CERS, upload the completed form, and submit for review by the <br /> EHD. Ensure a copy is available for inspection at any time. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Provide a legend to the site plan. A site plan must De <br /> submitted identifying the locations where monitoring will be performed. Immediately log into the California <br /> Environmental Reoorting System (CERS) at http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site <br /> Plan. <br /> This is a minor violation. <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> The Response Plan was not submitted to the the California Electronic Reporting System (CERS). Beginning <br /> January 1, 2014, all businesses are required to submit all new (or any changes to existing) UST information, <br /> including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, UST <br /> Owner/Operator Written Agreement(if applicable), UST Letter from Chief Financial Officer, and Owner Statement of <br /> Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to include any <br /> other relevant activities and required fields. <br /> This is a minor violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): VICKI MCCARTNEY, Senior REHS (209) 468-9852 12/21/2015 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.