Laserfiche WebLink
E <br /> San Joaquin County <br /> !! Environmental Health Department , <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 i <br /> Telephone:(209)468-3420 Fax;(209)468-3433 Web:www,si-gov.ora/ehd <br /> Facility Name: Facility Address: Date: h <br /> i FOOD LESS FUEL CENTER* <br /> ' T' 3408 MANTHEY RD,STOCKTON February 18,2015 <br /> i40 t PW <br /> _' "UST,Systcrt ;Observations } ; : ? %�s 4 , <br /> - ti''n « 9 a <br /> 322 CCR 2636(f)(2) Line leak detector not Installed a V .o R u COS <br /> k <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi a V o R o COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R o COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V a R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements a V o R o COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R a COS <br /> 329 CCR 2717.1(1) Deposited petroleum into a red tagged UST ❑V ❑R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R COS <br /> ❑ <br /> i <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R o COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V n R a COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R a COS <br /> rlk�a <br /> R "� Non'Pressuiizt'd piping -' '' ; `f <br /> -'iib... :ki '��+d.sat.. •s�K?srs.i`t.�,''r.:•:.�?' r. �:th^.t,;u 'fir .w.:l.: ::w .P, a. -,Cr. 9 t.�^� ,t,z,r F. <br /> 401 CCR 2636(x)(3) Suction piping not properly sloped or incorrectly located check valve ❑V o R a COS <br /> a <br /> 402 CCR 2643(d) Dally monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R u COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) u V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V a R ❑COS <br /> 2010 See below Unlisted Administration!Documentation violation o V a R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V o R u COS <br /> 2060 See below Unlisted DesigntConstruction violation n V o R ❑COS <br /> 6 <br /> A,S t '"`S' YF f •t .3 as <br /> + x t W'tSJll� <br /> wAm:4?.ra+r <br /> ;i sF+ f:.: a4 r:fa,dk�n ..4 i#_ -=Yx,.Rs%, .. t i .t+..tiP'.4 1�,x�!=, r. .-:., .�. ,fi r,r., .'�• - .y�va{. #N::, <br /> Item# Remarks <br /> 126 HSC 25404(e)(4)Failed to report program data electronically. <br /> A current submission to the California Electronic Reporting System(CERS)for the underground storage tank(UST) <br /> program has not been made. Beginning January 1,2014,all businesses are required to submit all new(or any <br /> changes to existing)UST information, including: UST Monitoring Site Plan, UST Certification of Financial <br /> a Responsibility, UST Response Plan, UST Owner/Operator Written Agreement(if applicable), UST Letter from Chief <br /> Financial Officer, and Owner Statement of Designated UST Operator Compliance online to the CERS at <br /> http:I/cers.calepa.ca.gov. Be sure to include any other relevant activities and required fields. Please see email <br /> sent today identifying specific items to upload and correct. These items were discussed with Gilbert onsite. This is <br /> a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement x <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> Received by(initial): nspector: one: Date: <br /> MICHELLE HENRY, Senior REHS (209)468-3454 02/18/2015 <br /> Page 3 of 4 <br /> .i <br /> t� <br />