Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD 4 LESS FUEL CENTER* 3408 MANTHEY RD, STOCKTON February 18, 2015 <br /> UST System Observations <br /> 322 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R ❑COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R ❑COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present,was overridden,or failed to meet overfill requirements ❑V ❑R ❑COS <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve u V ❑R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) V -i R -COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> A current submission to the California Electronic Reporting System (CERS) for the underground storage tank(UST) <br /> program has not been made. Beginning January 1, 2014, all businesses are required to submit all new (or any <br /> changes to existing) UST information, including: UST Monitoring Site Plan, UST Certification of Financial <br /> Responsibility, UST Response Plan, UST Owner/Operator Written Agreement(if applicable), UST Letter from Chief <br /> Financial Officer, and Owner Statement of Designated UST Operator Compliance online to the CERS at <br /> http://cers.calepa.ca.gov. Be sure to include any other relevant activities and required fields. Please see email <br /> sent today identifying specific items to upload and correct. These items were discussed with Gilbert onsite. This is <br /> a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will bet ken for each violation, and any supporting <br /> Received by(initial): Inspector: Phone: Date: <br /> MICHELLE HENRY, Senior REHS (209)468-3454 02/18/2015 <br /> Page <br />