My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Equipment Certification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name:Gas 4 Less Bldg.No.: <br /> Site Address: 3434 Manthey Road City: Stockton,CA Zip: 95206- <br /> Facility Contact Person: Manager Contact Phone No.: (209)234-7869 <br /> Make/Model of Monitoring System: V/R TLS-350 Date of Testing/Servicing: 2127114 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID:01-Regu Tank ID: 02-Prem <br /> ® In-Tank Gauging Probe. Model: VR 847390111 to In-Tank Gauging Probe. Model: VR 847390-111 <br /> ® Annular Space or Vault Sensor. Model: VR 794390460 ® Annular Space or Vault Sensor. Model: VR 794390.460 <br /> ® Piping Sump\Trench Sensor(s). Model: VR 794380-208 ® Piping Sump\Trench Sensor(s). Model: VR 794380209 <br /> ® Fill Sump Sensor(s). Model: VR 794380208 ® Fill Sump Sensor(s). Model: VR 794380-208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: VR Series 8494 ® Electronic Line Leak Detector. Model: VR series 8484 <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ 7ank Overfill\High-Level Sensor. Model: <br /> p Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank lA• <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID. 01-02 Dispenser ID: 03-04 <br /> ® Dispenser Containment Sensor(s). Model: VR 794380208 ® Dispenser Containment Sensor(s). Model: VR 794380208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: os-os EDenD: 07-08 <br /> 11 Dispenser Containment Sensor(s). Model: VR 794390-20a ontainment Sensor(s). Model: VR 794380208 <br /> Shear Valve(s). (s). <br /> Dispenser Containment Float(s)and Chain(s). ontainment Float(s)and Chain(s). <br /> Dispenser ID: 09-10 Dispenser ID• <br /> ® Dispenser Containment Sensor(s). Model: VR 794380.208 ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C.Certification- I certify that the equipment identified in this document was inspected/seryiced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (cbeckfg thatappf}•): ❑ System set-up ❑ Alarm history report <br /> Technician Name(print): Kris Bell Signature: �� <br /> Mfg.Cert.#.: B33709 ICC# 5297793-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems Phone No.: (408)971-2445 <br /> Testing Company Address: 680 Quinn Ave.,San Jose,CA 95112 Date of Testing/Servicing: 2/27/14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.